YOKOGAWA FG210-706111 CALIBRATION and YOKOGAWA FG210-706111 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA FG210-706111 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   YOKOGAWA FG210-706111   Description / Specification:    
YOKOGAWA FG210-706111 1-Ch 15 MHz Synthesized Function Generator

The Yokogawa 706111 FG210 1-channel Synthesized Function Generator features versatile sweep and modulation functions. These instruments offer you the capability to sweep not only frequency, but also other parameters as well, such as phase, amplitude, offset voltage, or duty cycle, with linear, log, linear step and log step. You can even sweep frequency and amplitude at the same time. Specifications. Output channels: 1 channel. Output waveforms: Sine, Square (fixed 50% duty cycle), Triangle (variable symmetry) or Pulse (variable duty cycle). Output signal: Continuous output(CONT): Waveform output continuously, Phase-continuous only. Triggered output (TRIG): Output preset number (integer) of burst waveforms on trigger sync. Gated output (GATE): Output integer number of burst waveforms while enabled by gate. DC output (DC): Output DC voltage. Frequency range: Sine or Square waveform 1 uHz to 15 MHz, Triangle or Pulse waveform 1 uHz to 200 kHz. Resolution: 1 uHz or 9 digits max. Frequency accuracy: ±20 ppm. Frequency stability: ±20 ppm (at ambient temperature of 5 to 40°C). Reference clock: 40.2107 MHz. Maximum output voltage: ±10 V. Amplitude setting range: ±20 Vpp (setting resolution 1 mVpp) (negative amplitude represents inverted waveform). Amplitude accuracy V(1 kHz sine wave): ±(0.8% of setting + 14 mVrms). Offset voltage setting range: ±10 V (setting resolution 1 mV). Offset voltage accuracy: ±(0.3% of setting + 0.5% of amplitude setting +40 mV). Output impedance: 50 ohm ±1% (open when output OFF). DC output setting range: ±10 V (setting resolution 1mV). DC output accuracy: ±(0.3% of setting + 20 mV). Output attenuator setting range: 1/1, 1/10, 1/100. Output attenuator accuracy: 0.2%. Option. /R1, External sweep control.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA FG210-706111. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your YOKOGAWA FG210-706111 CALIBRATION and/or YOKOGAWA FG210-706111 1-Ch 15 MHz Synthesized Function Generator REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: