A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA FG310-706121 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   YOKOGAWA FG310-706121   Description / Specification:    
YOKOGAWA FG310-706121 1-Ch 15 MHz Synthesized Function Generator

The Yokogawa 706121 FG310 1-channel Synthesized Function Generator (with arbitrary sweep and simple arbitary waveform generator functions) features versatile sweep and modulation functions. These instruments offer you the capability to sweep not only frequency, but also other parameters as well, such as phase, amplitude, offset voltage, or duty cycle, with linear, log, linear step, log step, or arbitrary sweep patterns. You can even sweep frequency and amplitude at the same time. Offering up to 256 programmed sequence steps. Specifications. Output channels: 1 channel. Output waveforms: Sine, Square (fixed 50% duty cycle), Triangle (variable symmetry), Pulse (variable duty cycle), or Arbitrary waveform. Output signal: Continuous output(CONT): Waveform output continuously, Phase-continuous only. Triggered output (TRIG): Output preset number (integer) of burst waveforms on trigger sync. Gated output (GATE): Output integer number of burst waveforms while enabled by gate. DC output (DC): Output DC voltage. Frequency range: Sine or Square waveform 1 uHz to 15 MHz, Triangle or Pulse waveform 1 uHz to 200 kHz, Arbitrary waveform 1 uHz to 200 kHz. Resolution: 1 uHz or 9 digits max. Frequency accuracy: ±20 ppm. Frequency stability: ±20 ppm (at ambient temperature of 5 to 40°C). Reference clock: 40.2107 MHz. Maximum output voltage: ±10 V. Amplitude setting range: ±20 Vpp (setting resolution 1 mVpp) (negative amplitude represents inverted waveform). Amplitude accuracy V(1 kHz sine wave): ±(0.8% of setting + 14 mVrms). Offset voltage setting range: ±10 V (setting resolution 1 mV). Offset voltage accuracy: ±(0.3% of setting + 0.5% of amplitude setting +40 mV). Output impedance: 50 ohm ±1% (open when output OFF). DC output setting range: ±10 V (setting resolution 1mV). DC output accuracy: ±(0.3% of setting + 20 mV). Output attenuator setting range: 1/1, 1/10, 1/100. Output attenuator accuracy: 0.2%. Option. /R1, External sweep control.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA FG310-706121. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your YOKOGAWA FG310-706121 CALIBRATION and/or YOKOGAWA FG310-706121 1-Ch 15 MHz Synthesized Function Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: