YOKOGAWA DL2700-700882 CALIBRATION and YOKOGAWA DL2700-700882 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA DL2700-700882 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   YOKOGAWA DL2700-700882   Description / Specification:    
YOKOGAWA DL2700-700882 8 Ch 150 MHz Long Memory Digital Oscilloscope

The Yokogawa DL2700-700882 Multi-channel Long Memory Digital Oscilloscope, with a maximum record length of 4 MW, features more than just a long record length. We designed this instrument to facilitate long record measurement work. This digital oscilloscope can efficiently capture abnormal phenomena buried in long data, allowing you to search for and analyze the causes of these abnormal phenomena. We made the record length per channel as long as possible to enable you to carry out efficient troubleshooting. We also designed the instrument to measure data in at least six channels, enabling you to determine the cause and effect relationship between each signal. The instrument also has excellent zoom operability to permit analysis of captured waveforms. Specifications. Frequency Band: DC to 150 MHz. 8 input channels. Input impedance: 1 M ohm ±1.5% (approx. 16 pF). Trigger Sensitivity: 1 div p-p (DC to 150 MHz). Vertical Voltage axis sensitivity: 2 mV/div to 5 V/div. Horizontal Time axis accuracy: ±(0.01% + 500 ps), Sweep time: 2 ns/div to 50 s/div. Sampling rate; Max: 500 MS/s, Per channel: 200 MS/s. Record length; Max: 4 M words, Per channel: 2 M words. Number of channels that can be used at the max sampling rate or max record length: 4. Display, LCD: 8.4-inch TFT, color (640 x 480 dots).



 

Standard Calibration $415.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA DL2700-700882. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your YOKOGAWA DL2700-700882 CALIBRATION and/or YOKOGAWA DL2700-700882 8 Ch 150 MHz Long Memory Digital Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: