YOKOGAWA DL7200-701440 CALIBRATION and YOKOGAWA DL7200-701440 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA DL7200-701440 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   YOKOGAWA DL7200-701440   Description / Specification:    
YOKOGAWA DL7200-701440 4 Ch 500 MHz SignalExplorer Digital Oscilloscope

The Yokogawa DL7200-701440 SignalExplorer was designed to satisfy the key feature requirements for waveform measuring systems. These features are: Simple and accurate capturing of complex signals. High-speed extraction and screen display of desired information from large volumes of captured data. Specifications. DC to 500 MHz Bandwidth. Input channels: 4 analog (CH1 through CH4) and 16-bit digital (optional). Input impedance: 1 M-ohm ±1.0%, approx. 20 pF, 50 ohm ±1.0% (V SWR 1.4 or less (DC to 500 MHz)). Voltage-axis sensitivity setting: 1 M-ohm input : 2 mV/div to 10 V/div (1 - 2 - 5 steps), 50 ohm input : 2 mV/div to 1 V/div (1 - 2 - 5 steps). Time axis range: 1 ns/div to 50 s/div (record length is 10 k Words or more), 1 ns/div to 5 s/div (record length is 1 k Words). Time base precision: ±(0.005%). Maximum sample rate Realtime sampling mode: With interleave ON : 2 GS/s, With interleave OFF : 1 GS/s. Maximum record length: With interleave ON : 16 MWords/CH, With interleave OFF: 8 MWords/CH. Display 8.4 - inch (approx. 21.3 cm) color TFT liquid crystal display.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA DL7200-701440. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your YOKOGAWA DL7200-701440 CALIBRATION and/or YOKOGAWA DL7200-701440 4 Ch 500 MHz SignalExplorer Digital Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: