YOKOGAWA DL750P-701230 CALIBRATION and YOKOGAWA DL750P-701230 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA DL750P-701230 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Data Acquisition?
Shop for Comparable Products on our
 used Data Acquisition page

 
   YOKOGAWA DL750P-701230   Description / Specification:    
YOKOGAWA DL750P-701230 Digital Oscilloscope / Chart Recorder Mainframe

The Yokogawa DL750P-701230 Digital Oscilloscope / Chart Recorder Mainframe (16 isolated channels + 16-bit logic) 210 mm width A4 thermal printer built-in. Features. Number of Slots 8 (up to 16 channels). Maximum sampling rate: 10 MS/s (module dependent). Logic inputs: 16 (8 bits x 2). Max. record length: Standard 2.5 MW/CH, 50 MW total; /M1 10 MW/CH, 250 MW total; /M2 25 MW/CH, 500 MW total; /M3 50 MW/CH, 1 GW total. Time axis accuracy: ±0.005%. Time axis setting range: 500 ns-30 sec/div, 1 min-30 min/div, 1 h-12 h/div, 1 day-3 days/div (up to 30 days). Acquisition modes Normal, Envelope, Averaging, Box average. Display: 10.4-inch color TFT liquid crystal display (SVGA 800 x 600 dots). 210 mm width A4 thermal printer built-in. Plug-in Modules. 701250, High-speed 10 MS/s 12-bit isolation module (2 CH). 701251, High-speed 1 MS/s 16-bit isolation module (2 CH). 701255, High-speed 10 MS/s 12-bit non-isolation module (2 CH). 701260, High-voltage 100 kS/s 16-bit isolation module (2 CH, with RMS). 701261, Universal Module (2 CH). 701262, Universal Module (with AAF 2 CH). 701265, Temperature/high-precision voltage module (2 CH). 701270, Strain module (NDIS, 2 CH). 701271, Strain module (DSUB, Shunt-CAL, 2 CH). 701275, Acceleration/voltage module (with AAF, 2 CH). 701280, Frequency module (2 CH).



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA DL750P-701230. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your YOKOGAWA DL750P-701230 CALIBRATION and/or YOKOGAWA DL750P-701230 Digital Oscilloscope / Chart Recorder Mainframe REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: