YOKOGAWA 73402 CALIBRATION and YOKOGAWA 73402 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 73402 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   YOKOGAWA 73402 (734-02)   Description / Specification:    
YOKOGAWA 73402 5 Digit Digital Multimeter

The Yokogawa 734 02 is a 5-digit Digital Multimeter with Bar graph indicator. It supports a variety of measurement functions; DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature, Capacitor, Duty cycle ratio, Decibel (dB), Averaging when the measured value may greatly fluctuate, Relative values from the reference measurement values (REL delta), Minimum value (MIN), Maximum value (MAX), Average value (AVG), Range Hold (R•H), Data Hold (D•H), Auto Hold (A•H), Peak Hold* (P•H), Continuity Check, Zero Adjustment (Capacitor, Resistance), Diode Test, Save to Memory, LCD backlight. Downloading of measurement data to a personal computer using optional communication package. DC Voltage Measurement Ranges: 50 mV to 1000 V. DC Voltage Resolution: 0.001mV @ 50 mV, 0.1V @ 1000 V. DC Voltage Accuracy: 0.05+10 @ 50 mV, 0.03+2 @ 1000 V. AC Voltage Measurement Ranges: 500 mV to 1000 V. AC Voltage Resolution: 0.01mV @ 500 mV, 0.1V @ 1000 V. DCV + ACV (Maximum Reading 5000, Crest factor: <3) Ranges: 5 V to 1000 V. DCV + ACV (Maximum Reading 5000, Crest factor: <3) Resolution: 0.01 V @ 5 V, 1V @ 1000 V. DC Current Measurement Ranges: 500 uA to 10 A. DC Current Resolution: 0.01 uA @ 500 uA, 0.001 A @ 10 A. DC Current Accuracy: 0.2+2 @ 500 uA, 0.6+2 @ 10 A. AC Current Measurement Ranges: 500 uA to 10 A. AC Current Resolution: 0.01 uA @ 500 uA, 0.001 A @ 10 A. DCA + ACA(Crest factor: <3) Ranges: 500 uA to 10 A. DCA + ACA(Crest factor: <3) Resolution: 0.1 uA @ 500 uA, 0.01 A @ 10 A. Resistance Measurement Range: 500 ohm to 50 M-ohm. Resistance Measurement Resolution: 0.01 ohm @ 500 ohm, 0.001 M-ohm @ 50 M-ohm. Temperature Measurement Range: -50 to 800°C and -58 to 1472°F. Capacitor Measurement Range: 5 nF to 50 mF. Frequency Measurement Range: 2.000 Hz to 99.99 kHz.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 73402. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your YOKOGAWA 73402 CALIBRATION and/or YOKOGAWA 73402 5 Digit Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: