Keysight (Agilent) 16803A CALIBRATION and Keysight (Agilent) 16803A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 16803A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) 16803A   Description / Specification:    
Keysight (Agilent) 16803A 102-Ch Portable Logic Analyzer

The Agilent 16803A 102 channel Portable Logic Analyzer lets you make accurate high-speed timing measurements with 4 GHz (250 ps) high-speed timing zoom. A parallel acquisition architecture provides high-speed timing measurements simultaneously through the same probe used for state or timing measurements. Timing zoom stays active all the time with no tradeoffs. View data at high resolution over longer periods of time with 64-K-deep timing zoom. Specifications and Characteristics. Logic analyzer channels: 102, (98 data + 4 clocks), Unused clock channels can be used as data channels. High-speed timing zoom: 4 GHz (250 ps) with 64 K depth. Maximum timing sample rate (Half/full ch): 1.0 GHz (1.0 ns) / 500 MHz (2.0 ns). Memory depth in full channel mode: based on option installed, 1 to 32 M. Maximum trigger sequence speed: 250 MHz. Maximum trigger sequence levels: 16. Trigger sequence level branching: Arbitrary 4-way if/then/else. Trigger position: Start, center, end, or user-defined. LCD display: 38.1-cm (15-in.) display makes is easy to view a large number of waveforms or states. Options; -001, 1 M Memory depth. -004, 4 M Memory depth. -016, 16 M Memory depth. -032, 32 M Memory depth. -250, 250 MHz State speed. -500, 450 MHz State speed. -101, Internal Hard Drive. -102, Front Panel with 15” Display. -103, Front Panel with 15” Display Touch screen. -109, External removable hard drive.



 

Standard Calibration $690.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 16803A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 16803A CALIBRATION and/or Keysight (Agilent) 16803A 102-Ch Portable Logic Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?