A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 16803A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) 16803A   Description / Specification:    
Keysight (Agilent) 16803A 102-Ch Portable Logic Analyzer

The Agilent 16803A 102 channel Portable Logic Analyzer lets you make accurate high-speed timing measurements with 4 GHz (250 ps) high-speed timing zoom. A parallel acquisition architecture provides high-speed timing measurements simultaneously through the same probe used for state or timing measurements. Timing zoom stays active all the time with no tradeoffs. View data at high resolution over longer periods of time with 64-K-deep timing zoom. Specifications and Characteristics. Logic analyzer channels: 102, (98 data + 4 clocks), Unused clock channels can be used as data channels. High-speed timing zoom: 4 GHz (250 ps) with 64 K depth. Maximum timing sample rate (Half/full ch): 1.0 GHz (1.0 ns) / 500 MHz (2.0 ns). Memory depth in full channel mode: based on option installed, 1 to 32 M. Maximum trigger sequence speed: 250 MHz. Maximum trigger sequence levels: 16. Trigger sequence level branching: Arbitrary 4-way if/then/else. Trigger position: Start, center, end, or user-defined. LCD display: 38.1-cm (15-in.) display makes is easy to view a large number of waveforms or states. Options; -001, 1 M Memory depth. -004, 4 M Memory depth. -016, 16 M Memory depth. -032, 32 M Memory depth. -250, 250 MHz State speed. -500, 450 MHz State speed. -101, Internal Hard Drive. -102, Front Panel with 15” Display. -103, Front Panel with 15” Display Touch screen. -109, External removable hard drive.



 

Standard Calibration $690.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 16803A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) 16803A CALIBRATION and/or Keysight (Agilent) 16803A 102-Ch Portable Logic Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: