FLUKE I410 CALIBRATION and FLUKE I410 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE I410 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE I410   Description / Specification:    
FLUKE I410 400 Amp AC/DC Current Clamp Meter

The Fluke i410 AC/DC Current Clamp / Hall-effect probe expands the functionality of digital multimeters and measures up to 400 amps for both AC and DC current. 1mV/Amp output guarantees easy, accurate readings without breaking the circuit. The Large clamp claw gives you access to difficult to reach areas. It features a CAT III 600 V safety rating.
Specifications.

Max. conductor: 32 mm.
Measurement type: Hall sensor.
Nominal current range: 400 A, AC/DC.
Continuous current range: 1 A - 400 A AC/DC.
Maximum non-destructive current: 400 A.
Lowest measurable current: 0.5 A.
Basic accuracy: 3.5% + 0.5 A (% reading + floorspec).
Usable frequency: DC - 3 kHz.
Output level(s): 1 mV/A.
Zero error adjustment: Yes.



 

Standard Calibration $260.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE I410. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your FLUKE I410 CALIBRATION and/or FLUKE I410 400 Amp AC/DC Current Clamp Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: