Keysight (Agilent) N5182A CALIBRATION and Keysight (Agilent) N5182A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N5182A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) N5182A   Description / Specification:   Spec Sheet 
Keysight (Agilent) N5182A 3/6 GHz MXG RF Vector Signal Generator

The Agilent N5182A MXG RF Vector Signal Generator features fast frequency, amplitude, and waveform switching, industry-best ACPR performance, high reliability, and simplified self-maintenance – all in two rack units (2RU) – Agilent N5182A MXG vector is optimized for manufacturing cellular communications and wireless connectivity components. Agilent MXG vector provides better value for your investment by increasing throughput, improving test yield, maximizing uptime, and saving rack space. With scalable RF and baseband performance, the Agilent N5182A MXG vector is easily configured to meet your specific test needs. Features. –70 dBc ACPR for 4-carrier W-CDMA. Decrease test uncertainty in manufacturing and increase yields. Better device characterization in R&D. Arbitrary switching of frequency, amplitude, or waveforms in <= 1.2 ms. Simultaneously frequency, amplitude, and waveforms switching with list mode in <= 900 µs. Generate wide bandwidth signals up to 100 MHz. 64 MSa of memory for waveform playback. 16-bit DACs for excellent dynamic range. Hardware resampling technology eliminates need for multiple reconstruction filters. Electronic attenuator up to 6 GHz. 160 MHz I/Q modulation bandwidth. Specifications. Frequency Range: 100 kHz to 3 GHz (Option 503), 100 kHz to 6 GHz (Option 506). Minimum Frequency: 100 kHz. Resolution: 0.01 Hz. Phase Offset: Adjustable in 0.01°. Stability, Internal Time Base Reference Oscillator Aging Rate: <= ± 5 ppm/10 yrs, < ± 1 ppm/yr. Stability, Temperature effects: ±1 ppm (0 to 55°C). Reference Output: Frequency 10 MHz, Amplitude >= +4 dBm (nom) into 50 ohm load. Sweep Modes: Frequency Step, Amplitude Step and Arbitrary List. Amplitude Output Power: –110 to +13 dBm (max). Resolution: 0.02 dB (nom): Step Attenuator: 0 to 130 dB in 5 dB steps, electronic type. Options. Opt 503: Frequency Range from 100 kHz to 3 GHz. Opt. 506: Frequency Range from 100 kHz to 6 GHz. Opt UNZ: Fast Switching 1EQ Low Power (<–110 dBm). Opt UNU: Pulse Modulation. Opt UNW: Narrow Pulse Modulation. Opt UNT: AM, FM, Phase Modulation. Opt 006: Instrument Security. Opt 1ER: Flexible Reference Input (1 – 50 MHz). Opt 1EM: Move RF Output to Rear Panel. Opt 651: Internal Baseband Generator (30 MSa/s, 8 MSa). Opt 652: Internal baseband Generator (60 MSa/s, 8 MSa). Opt 654: Internal Baseband Generator (125 MSa/s, 8 MSa). Opt 019: Increase Baseband Generator Memory to 64 MSa. Opt 1EL: Differential I/Q Outputs. Opt UNV: Enhanced Dynamic Range. Opt 403: Calibrated AWGN. Opt 430: Multitone and Two-tone. Opt 431: Custom Digital Modulation. Opt 432: Phase Noise Impairment.



 

Standard Calibration $890.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N5182A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) N5182A CALIBRATION and/or Keysight (Agilent) N5182A 3/6 GHz MXG RF Vector Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: