RACAL DANA 3152A CALIBRATION and RACAL DANA 3152A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the RACAL DANA 3152A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   RACAL DANA 3152A   Description / Specification:    
RACAL DANA 3152A Precision PLL Waveform Synthesizer, VXI

Racal Instruments 3152A Precision PLL Waveform Synthesizer VXI module, Amplitude Characteristics: Amplitude 20 mV - 32 Vpk-pk, output open circuit, 10 mV - 16 Vpk-pk, into 50 ohm; Resolution 3.5 digits, Accuracy (at 1 kHz and specified output) ±1% of setting; Amplitude Ranges: R1: 10.00 mV-160.0 mV, R2: 160.1 mV-1.600 V, R3: 1.601 V-16.00 V, Accuracy (at 1 kHz), ±1% of setting; DC Offset Range 0 to ± 7.19 V, DC Offset Accuracy, R1: ±(1% Vampl. +1% Vofs. +0.2 mV), R2: ±(1% Vampl. +1% Vofs. +2 mV), R3: ±(1% Vampl. +1% Vofs. +20 mV), Waveform Dynamic Range: Vampl + Vofs. = max. of selected, amplitude range: 12bits, Vampl. + Vofs. > max. of selected, amplitude range: <12 bits, (derates as Vofs. is increased), Low-Pass Filters 20 MHz, 7-pole, Gaussian, 25 MHz, 7-pole, elliptic, 50 MHz, 7-pole, elliptic, Standby (Output disconnected), Output On or Off, Output Protection, Short circuit, Glitch Energy, 1 nV-s at 16 Vpk-pk. Standard Waveforms: Sinex, Trianglex, Square, Pulse, Ramp, Sinc, Gaussian Pulse, Exponential Decay Pulse, Exponential Rise Pulse, DC, Frequency Resolution 7 digits, Accuracy ±.01% of setting, Stability 1 ppm.



 

Standard Calibration $520.00 *
*This is a Web introductory price for one calibration of the RACAL DANA 3152A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your RACAL DANA 3152A CALIBRATION and/or RACAL DANA 3152A Precision PLL Waveform Synthesizer, VXI REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: