ROHDE & SCHWARZ NRVD CALIBRATION and ROHDE & SCHWARZ NRVD REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ NRVD Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Meter?
Shop for Comparable Products on our
 used RF Power Meter page

 
   ROHDE & SCHWARZ NRVD (857.8008.02)   Description / Specification:    
ROHDE & SCHWARZ NRVD Dual-Channel RF Power Meter

The Rohde & Schwarz NRVD covers a total bandwidth of 40 GHz and a power span from 100 pW up to the kW range. Being individually and absolutely calibrated,the sensors can be interchanged as required without impairing measurement accuracy. The NRVD is not just a powermeter with two inputs; it functions like two independent measuring instruments in one cabinet that perform measurements simultaneously and exchange data with one another. The two channels can be separately set so that two completely different measurements can be carried out at the same time. The two measured values can also be related to each other for direct indication of reflection coefficient, SWR and return loss, for instance, when a SWR bridge is connected to the meter. The Test Generator makes it possible to check the connected sensors for damageor destruction, e.g. afteroverloading or excessive mechanical stress. It generates a low-distortion, highly accurate 50 MHz signal of 1 mW power (0 dBm). Specifications. Measurement functions: unmodulated and modulated power (average power, pulse power, peak envelope power, AM), reflection, DC and AC voltage (depending on sensor). Frequency and level range: DC to 40 GHz, 100 pW to 30 W (depending on sensor). Sensors: all R&S¸NRV-Z and R&S URV5-Z voltage and power sensor. Display: LCD for figures, units, user prompting and analog display; adjustable backlighting. Resolution of digital display: 5 digits max., resolution adjustable in 3 steps: HIGH: 12000 steps or 0.001 dB; MEDIUM: 1200 steps or 0.01 dB; LOW: 120 steps or 0.1 dB. Averaging filter: over 1 to 512 readings for reducing the display noise. Test generator Output power: 1.00 mW; factory set to ±0.7 % (traceable to PTB). Test generator Frequency: 50 MHz.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ NRVD. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your ROHDE & SCHWARZ NRVD CALIBRATION and/or ROHDE & SCHWARZ NRVD Dual-Channel RF Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: