A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N7744A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Power Meter?
Shop for Comparable Products on our
 used Optical Power Meter page or new Optical Power Meter page

 
   Keysight (Agilent) N7744A   Description / Specification:    
Keysight (Agilent) N7744A 4-Ch Optical Multiport Power Meter

The Agilent N7744A optical power meter with four power-sensor channels provides increased throughput and operational efficiency to meet today's challenges in manufacturing. Designed for characterizing optical multiport components, these optical power meters offer industry-leading solutions for device connectivity, high-speed measurement data acquisition and fast data transfer for post-processing. The multiport power meter enables fast measurement solutions for all multiport devices; for example multiplexers, PON splitters, wavelength selective switches (WSS) and ROADMs, as well as compact setups for simultaneous testing of multiple single-port devices. The N7744A power meter uses the unprecedented N7740 fiber connectivity concept, which is a quadruple adapter (quad-adapter) with a snap-on quick-locking mechanism. The device to be tested can be connected to the quad-adapter in a comfortable ergonomic working position, even while the instrument is measuring another device. Then the quad-adapter can quickly be snapped on, to provide repeatably high-precision connections. Specifications. Sensor element: InGaAs. Wavelength range: 1250 nm to 1650 nm. Specification wavelength range: 1250 nm to 1625 nm (if not stated differently). Power range: -80 dBm to +10 dBm. Maximum safe power: +16 dBm. Data logging capability: 2 buffers per port, each with capacitiy for 1 Mio. measurement points. Averaging time: 1 µs to 10 s. Applicable fiber type: Standard SM and MM <= 62.5 µm core size, NA <= 0.24. Uncertainty at reference conditions: ±2.5%. Total uncertainty: ±4.5%. Relative port to port uncertainty: typ. ±0.05 dB. Linearity at (23 ± 5) C: ±0.02 dB ± 3 pW. Polarization dependent responsivity: < ±0.015 dB (1520 nm to 1580 nm). Return loss: > 50 dB (1520nm to 1580nm). Fully compliant to LXI Class C specifications. LAN, USB and GPIB programming interfaces. Code compatibility to Agilent’s Lightwave measurement system platform.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N7744A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Broadband Source (BBS)
A Broadband Source is a spectrally large source that emits a signal which contains a continuous range of frequencies with a broad optical bandwidth (usually 100 nm or more). Sometimes called a white light source, there are two different meanings of this term. Visible white light and a source which does not necessarily emit in the visible spectral region.

Coherence
Coherence is the pattern and or relationships of waves due to phase properties.

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Power Flatness Over Modulation
When changing the wavelength and modulation frequency, and measuring the differences between actual and displayed power levels (in dB), the power flatness is ± half the span between the maximum and the minimum value of all differences.

Singlemode fiber
Singlemode Fiber has a small core, only about 9 microns, and is used for telephony and CATV with laser sources at 1300 and 1550 nm. It can go very long distances at very high speeds. Both multimode and singlemode fiber have an outside diameter of 125 microns - about 5 thousandths of an inch - just slightly larger than a human hair.


Please contact us for your Keysight (Agilent) N7744A CALIBRATION and/or Keysight (Agilent) N7744A 4-Ch Optical Multiport Power Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: