EXTECH INSTRUMENTS MN26T CALIBRATION and EXTECH INSTRUMENTS MN26T REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS MN26T Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS MN26T   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS MN26T Auto Ranging MiniTec Digital MultiMeter with Temp

The Extech MN26T Auto Ranging MiniTec Digital MultiMeter features 4000 counts on large LCD with full function indication. Specifications. DC Voltage Ranges: 200mV, 2V, 20V, 200V, 600V. DC Voltage Maximum Resolution: 0.1 mV. DC Voltage Accuracy: ± (0.5% reading + 2 digits). AC Voltage Ranges: 200V, 600V. AC Voltage Maximum Resolution: 0.1 V. AC Voltage Accuracy (Frequency 50/60Hz): ± (1.5% reading + 5 digits). DC Current Ranges: 200mA, 10A. DC Current Maximum Resolution: 100 µA. DC Current Accuracy: 200mA ± (1.2% reading + 2 digits), 10A ± (2.0% reading + 2 digits). AC Current Ranges: 200mA, 10A. AC Current Maximum Resolution: 100 µA. AC Current Accuracy: 200mA ± (1.8% reading + 5 digits), 10A ± (3.0% reading + 5 digits). Resistance Ranges: 200, 2k, 20k, 200k, 2Mohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Accuracy: 200, 2k, 20k, 200kohm ± (0.8% reading + 2 digits), 2Mohm ± (1.0% reading + 2 digits). Capacitance Ranges: 4 nF, 40 nF, 400 nF, 4 µF, 40 µF, 200 µF. Capacitance Maximum Resolution: 0.001 nF. Capacitance Basic Accuracy: ±3.5%. Frequency Ranges: 0.001 Hz to 10 MHz. Frequency Maximum Resolution: 0.001 Hz. Frequency Basic Accuracy: ±1.5%. Temperature Ranges: 0 to 1400°F (0 to 760°C ). Temperature Maximum Resolution: 1°F/°C. Temperature Basic Accuracy: ±3.0%. Duty Cycle: 0.1% to 99.9%. Duty Cycle Maximum Resolution: 0.1%. Duty Cycle Basic Accuracy: ±1.2%. Display: 3 1/2 digit, 2000 count LCD, 0.5” digits. Diode Test: Test current of 0.3mA maximum, open circuit voltage 1.5V DC typical.



 

Standard Calibration $180.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS MN26T. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your EXTECH INSTRUMENTS MN26T CALIBRATION and/or EXTECH INSTRUMENTS MN26T Auto Ranging MiniTec Digital MultiMeter with Temp REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: