A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 7700 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   KEITHLEY 7700   Description / Specification:    
KEITHLEY 7700 20-Channel Differential Multiplexer w/Automatic CJC

The Keithley 7700 20-Channel Differential Multiplexer w/Automatic CJC features; 20 channels of 2-pole relay input. All channels configurable to 4-pole. 2 channels of current only input. Latching electromechanical relay. Actuation Time:< 3ms. 2- or 4-wire measurement. Oversize screw terminal connection blocks are standard for easier connections. Automatic CJC sensors on the scanner card mean there are no other accessories are required to make thermocouple temperature measurements. 300V, 1A capacity for voltage channels; 60W, 125VA. 3A capacity for current channels.



 

Standard Calibration $240.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 7700. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Adjacent Channel Power
Adjacent Channel Power is the power from a modulated communications channel that leaks into an adjacent channel. This leakage is usually specified as a ratio to the power in the main channel, but is sometimes an absolute power.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.


Please contact us for your KEITHLEY 7700 CALIBRATION and/or KEITHLEY 7700 20-Channel Differential Multiplexer w/Automatic CJC REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: