Keysight (Agilent) DSO9404A CALIBRATION and Keysight (Agilent) DSO9404A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO9404A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO9404A   Description / Specification:    
Keysight (Agilent) DSO9404A 4-Ch 4 GHz Infiniium Analog Oscilloscope

The Agilent DSO9404A Infiniium 4 GHz, 4 analog channel oscilloscope is equipped with a 15” XGA display and comes in a package that is just 9” (23 cm) deep and weighs only 26 pounds (11.8 kg) to preserve your limited bench space. This scope is engineered to give you the broadest measurement capability available to meet your needs both today and in the future. Take advantage of optional integrated protocol viewers to quickly isolate physical layer issues causing errors. Analog bandwidth (–3 dB) 50 ohm: 4 GHz. Typical Rise Time / Fall Time 10% to 90% at 50 ohm: 85 ps. Typical Rise Time / Fall Time 20% to 80% at 50 ohm: 59 ps. Input channels: 4 analog. Input impedance: 50 ohm ± 2.5%, 1 Mohm ± 1% (11pF typical). Input sensitivity: 1 Mohm: 1 mV/div to 5 V/div, 50 ohm: 1 mV/div to 1 V/div. Bandwidth limit: 20 MHz on 1 MO input ; 500 MHz up to full scope bandwidth in increments of 500 MHz. Vertical resolution: 8 bits, =12 bits with averaging. DC gain accuracy: ± 2% of full scale at full resolution on channel scale ± 5 °C from cal temp. Maximum input voltage: 1 Mohm: 150V RMS or DC, CAT I ± 250 V (DC + AC) in AC coupling, 50 ohm: 5 Vrms. Horizontal; Channel-to-channel skew (digital): 2 ns typical. Glitch detect (digital): >= 2.0 ns. Main time base range: 5 ps/div to 20 s/div. Horizontal position range: 0 to ± 200 s. Delayed sweep range: 1 ps/div to current main time base setting. Resolution: 1 ps. Modes: Main, delayed, roll (200 ms to 20 sec). Maximum real-time sample rate: 4 ch x 10 GS/s or 2 ch x 20 GS/s. Option 50M, 50 Mpts on 4 channels, 100 Mpts on 2 channels. Option 100, 100 Mpts on 4 channels, 200 Mpts on 2 channels. Option 200, 200 Mpts on 4 channels, 400 Mpts on 2 channels. Option 500, 500 Mpts/ 250 Mpts on 4 channels, 1 Gpts/ 500 Mpts on 2 channels (single/repetitive mode).



 

Standard Calibration $565.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO9404A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) DSO9404A CALIBRATION and/or Keysight (Agilent) DSO9404A 4-Ch 4 GHz Infiniium Analog Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: