KEITHLEY 6517B CALIBRATION and KEITHLEY 6517B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEITHLEY 6517B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   KEITHLEY 6517B   Description / Specification:    
KEITHLEY 6517B Electrometer / High Resistance Meter

The Keithley 6517B 5½-digit Electrometer/High Resistance Meter offers accuracy and sensitivity specifications unmatched by any other meter of this type. Italso offers a variety of features that simplifies measuring high resistances and the resistivity of insulating materials. With reading rates of up to 425 readings/ second, the Model 6517B is also significantly faster than competitive electrometers, so it offers a quick, easy way to measure low-level currents. The half-rack-sized Keithley 6517B has a special low current input amplifier with an input bias current of < 3 fA with just 0.75 fA p-p (peak-to-peak) noise and < 20 µV burden voltage on the lowest range. The input impedance for voltage and resistance measurements is 200 T-ohm for near-ideal circuit loading. These specifications ensure the accuracy and sensitivity needed for accurate low current and high imped ance volt age, resistance, and charge measure ments in areas of research such as physics, optics, nanotechnology, and materials science. A built-in ±1 kV voltage source with sweep capability simplifies performing leak age, break down, and resis tance testing, as well as volume (ohm-cm) and surface resistivity (ohm/square) mea sure ments on insulating materials.



 

Standard Calibration $240.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEITHLEY 6517B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your KEITHLEY 6517B CALIBRATION and/or KEITHLEY 6517B Electrometer / High Resistance Meter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: