EXTECH INSTRUMENTS EX830 CALIBRATION and EXTECH INSTRUMENTS EX830 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX830 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   EXTECH INSTRUMENTS EX830   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS EX830 1000 Amp AC/DC True RMS Clamp/DMM+IR Thermometer

The Extech EX830 1000 Amp True RMS AC/DC Clamp Meter with IR Thermometer multimeter functions include, AC/DC Voltage and Current, Resistance, Capacitance, Frequency, Diode, Continuity and Type K Thermometer. Features include Data Hold and Min/Max. Autoranging with manual range button. Peak hold captures inrush currents and Transients. 4000 count backlit display. Specifications. AC Current: 0.1 to 1000A. AC Current Basic Accuracy: ±2.5%. DC Current: 0.1 to 1000A. DC Current Basic Accuracy: ±2.5%. AC Voltage: 0.1mV to 600V. AC Voltage Basic Accuracy: ±1.5%. DC Voltage: 0.1mV to 600V. DC Voltage Basic Accuracy: ±1.5%. Resistance: 0.1 to 40 Mohm. Resistance Basic Accuracy: ±1.5%. Capacitance: 0.001nF to 40,000µF. Capacitance Basic Accuracy: ±3.0%. Frequency: 0.001 kHz to 4 kHz. Frequency Basic Accuracy: ±1.5%. Type K Temperature: -4 to 1400°F,-20 to 760°C. Type K Temperature Basic Accuracy: ±(3%rdg+9°F/5°C). IR Temperature (IR): -58 to 518°F, -50 to 270°C. IR Temperature (IR)Basic Accuracy: ±2.0% rdg or ±4°F/±2°C.



 

Standard Calibration $205.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS EX830. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your EXTECH INSTRUMENTS EX830 CALIBRATION and/or EXTECH INSTRUMENTS EX830 1000 Amp AC/DC True RMS Clamp/DMM+IR Thermometer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: