AMPROBE ACDC-100 CALIBRATION and AMPROBE ACDC-100 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE ACDC-100 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE ACDC-100   Description / Specification:   Spec Sheet 
AMPROBE ACDC-100 1000 Amp AC/DC Digital Clamp Multimeter

The Amprobe ACDC-100 1000A AC/DC Digital Clamp Multimeter offers superior AC/DC measurement capabilities, highest product quality and enhanced ergonomics. It features MAX capture function for inrush current measurements (30 ms response). Specifications. DC Voltage: 400.0 mV (Accuracy 0.3% + 3d), 4.000V, 40.00V, 400.0V (Accuracy 0.5% + 3d), 600V (Accuracy 1.0% + 4d). AC Voltage 50 Hz to 500 Hz: 400.0 mV, (Accuracy 4.0% + 4d). AC Voltage 50 Hz to 60 Hz: 4.000V, 40.00V, 400.0V, (Accuracy 1.0% + 4d). AC Voltage 60 Hz to 500 Hz: 4.000V, 40.00V, 400.0V, (Accuracy 1.5% + 4d). AC Voltage 50 Hz to 500 Hz: 600V, (Accuracy 2.0% + 4d). DC Current (Clamp-on) 400.0A: 0.0A to 400.0A (Accuracy 1.5% + 4d). DC Current (Clamp-on) 1000A: 400A to 800A (Accuracy 1.5% + 4d), 800A to 900A (Accuracy 2% + 4d), 900A to 1000A (Accuracy 5% + 30d). AC Current (Clamp-on) 400.0A: 15Hz to 40Hz (Accuracy 2.0% + 5d), 40Hz to 200Hz (Accuracy 1.5% + 5d), 200Hz to 400Hz@ <50A (Accuracy 1.5% + 5d), 400Hz to 1000Hz@ <50A (Accuracy 2% + 5d). AC Current (Clamp-on) 800A: 15Hz to 40Hz@ 400A to 600A (Accuracy 2.0% + 5d), 40Hz to 100Hz@ 400A to 600A (Accuracy 1.5% + 4d), 15Hz to 60Hz@ 600A to 800A (Accuracy 5% + 30d). Resistance: 400.0 ohm (Accuracy 0.8% + 6d), 4.000, 40.00, 400.0 kohm (Accuracy 0.6% + 4d), 4.000 Mohm (Accuracy 1.0% + 4d), 40.00 Mohm (Accuracy 2.0% + 4d). Capacitance: 500.0 nF, 5.000 µF, 50.00 µF, 500.0µF, 3000µF (Accuracy 3.5% + 6d). Display: 3-3/4 digits 4000 counts LCD display. Update Rate: 3 per second nominal.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE ACDC-100. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your AMPROBE ACDC-100 CALIBRATION and/or AMPROBE ACDC-100 1000 Amp AC/DC Digital Clamp Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: