ANDO VMG-1000 CALIBRATION and ANDO VMG-1000 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANDO VMG-1000 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ANDO VMG-1000   Description / Specification:    
ANDO VMG-1000 Highmegohm Meter

The Ando VMG-1000 Highmegohm Meter is designed to measure the insulation resistance of high-insulation materials, Up to 2 x 10^10 M-ohm of insulation resistance can be measured. This instrument can also be used as a highly sensitive ammeter to measure current in the range of 5 x 10^-14 to 2 x 10^-5 A. The VMG-1000 incorporates a timer for setting a specific amount of absorption current (charging current, etc.) after the measurement voltage has been applied, and also a GO/NO-GO decision function by means of a comparator, which enables initial setting of a measured value. This facilitates repeated measurements under the same conditions, convenient for component inspection. Use of this instrument will greatly raise efficiency not only in research and development work, but also in assembly line inspections. Specifications. Insulation resistance measurements: 5 M-ohm to 2 x 10^10 M-ohm, in 8 ranges. Accuracy: Meter needle range at 1/3 to 3/4 of full scale (Current scale is 7 to 15 uA), ± 4.5 % for 10^2 to 10^7 M-ohm range, ±8% for 10^8 M-ohm range, ± 10% for 10^9 M-ohm range. Short circuit current: Less than 1 mA. Current measurement: 5 x 10^-8 uA to 20 uA, in 8 ranges. Accuracy for full scale: ± 2 % for 1 to 10^-4 uA range.



 

Standard Calibration $625.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANDO VMG-1000. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your ANDO VMG-1000 CALIBRATION and/or ANDO VMG-1000 Highmegohm Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: