YOKOGAWA 701251 CALIBRATION and YOKOGAWA 701251 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701251 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701251   Description / Specification:    
YOKOGAWA 701251 2-Ch High-Speed 1 Ms/s 16-Bit Isolation Module

The Yokogawa 701251 High-Speed 1 Ms/s 16-Bit Isolation Module (2 ch) is used with the DL750, DL750P, SL1400 & SL1000 mainframes. Features a high sensitivity range (10 mV), low noise (±100 µVtyp), and high noise immunity. Specifications. Input channels: 2. Input couplings: AC, DC, GND. Maximum sample rate: 1 MS/s. A/D conversion resolution: 16 bits (24,000 LSB/range). Input type: Isolated unbalanced. Frequency range (-3 dB): DC, up to 300 kHz (50 mV to 200 V range). Input range (10:1): 100 mV to 2 kV range (in steps of 1, 2, or 5). Input range (1:1) 10 mV to 200 V range (in steps of 1, 2, or 5). Effective measurement range: 2 times the setting range. DC offset: 1/2 the setting range. Maximum input voltage: (1 kHz or less). DC accuracy: 50 mV to 200 V ± (0.25% of range). Input impedance: 1 M-ohm ± 1%, approximately 35 pF. Connector type: Isolated type BNC connector. Input filter: OFF, 400 Hz, 4 kHz, 40 kHz.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701251. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your YOKOGAWA 701251 CALIBRATION and/or YOKOGAWA 701251 2-Ch High-Speed 1 Ms/s 16-Bit Isolation Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: