YOKOGAWA 701260 CALIBRATION and YOKOGAWA 701260 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701260 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701260   Description / Specification:    
YOKOGAWA 701260 2-Ch High-voltage 100 kS/s 16-Bit Isolation Module

The Yokogawa 701260 High-voltage 100 kS/s 16-Bit Isolation Module (with RMS, 2 ch) is used with the DL750, DL750P, SL1400 & SL1000 mainframes. With RMS and high noise immunity. Specifications. Input channels: 2. Input couplings: AC, DC, GND, AC-RMS, DC-RMS. Maximum sample rate: 100 kS/s. A/D conversion resolution 16 bits (24,000 LSB/range). Input type: Isolated unbalanced. Frequency range (-3 dB) Waveform measurement mode: DC, up to 40 kHz. Frequency range (-3 dB) RMS mesurement mode: DC, 40 Hz to 10 kHz. Input range (10:1): 2 V to 20 kV range (in steps of 1, 2, or 5). Input range (1:1): 200 mV to 2 kV range (in steps of 1, 2, or 5). Effective measurement range: 2 times the setting range. DC offset: 1/2 the setting range. Maximum input voltage: (1 kHz or less). Input impedance: 1 M-ohm ± 1%, approximately 35 pF. Connector type: Isolated type BNC connector. Input filter: OFF, 100 Hz, 1 kHz, 10 kHz.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701260. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your YOKOGAWA 701260 CALIBRATION and/or YOKOGAWA 701260 2-Ch High-voltage 100 kS/s 16-Bit Isolation Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: