YOKOGAWA 701275 CALIBRATION and YOKOGAWA 701275 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701275 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701275   Description / Specification:    
YOKOGAWA 701275 2-Ch Acceleration /  Voltage Module (w Anti-Aliasing Filter)

The Yokogawa 701275 Acceleration / Voltage Module (with Anti-Aliasing Filter, 2 ch) is used with the DL750, DL750P, SL1400 & SL1000 mainframes. Built in Anti-Aliasing filter, supports built-in amp type acceleration sensors (4mA/22V). Specifications. Input channels: 2. Input type: Switchable between acceleration and voltage input AAF (anti-aliasing filter) supports both acceleration and voltage. Input couplings: (AC coupling for acceleration) ACCL, (voltage) AC, DC, GND. Maximum sample rate: 100 kS/s. A/D conversion resolution: 16 bit (24,000 LSB/range). Input type: Isolated unbalanced. Frequency band (-3 dB): (Acceleration) 0.4 Hz to 40 kHz (Voltage) DC, up to 40 kHz. AC coupling, Acceleration/voltage: 0.4 Hz or less. Input range for acceleration: (± 5 V = x 1 range) X0.1– x 1–X100 (in steps of 1, 2, or 5). Input range for voltage (10:1): 500 mV range to 1 kV range (in steps of 1, 2, or 5). Input range for voltage (1:1): 50 mV range to 100 V range (in steps of 1, 2, or 5). Effective measurement range: 2 times the setting range. DC offset: 1/2 the setting range. Maximum input voltage (1 kHz or less): 42 V (DC + ACpeak). Input impedance: 1 M-ohm ± 1%, approximately 35 pF. Connector type: Metal type BNC connector. Input filters: OFF, Auto (AAF), 4 kHz, 400 Hz, 40 Hz.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701275. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your YOKOGAWA 701275 CALIBRATION and/or YOKOGAWA 701275 2-Ch Acceleration / Voltage Module (w Anti-Aliasing Filter) REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: