YOKOGAWA 701855 CALIBRATION and YOKOGAWA 701855 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701855 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701855   Description / Specification:    
YOKOGAWA 701855 High-Speed 10 Ms/s 12-Bit Isolation Module

The Yokogawa 701855 High-Speed 10 Ms/s 12-Bit Isolation Module (1 ch) is used with the DL708, DL708E and DL716 mainframes. Specifications. Input channels: 1. Input couplings: DC, AC, GND. Maximum sample rate: 10 MS/s. A/D conversion resolution 12 bit (500 LSB/div). Input format: Isolated unbalanced. Frequency characteristics (-3 dB point when sine wave of amplitude ± 3 div is input): DC to 1 MHz. Voltage-axis sensitivity setting: 5 mV/div to 20 V/div (1-2-5 steps) when using 700929 : 50 mV/div to 200 V/div (1-2-5 steps). Maximum input voltage (At 1 kHz or less): main instrument only (across input terminals H and L) 250 V(DC+ACpeak)(CAT I and II, 177 Vrms) combined with 700929 (across probe tips H and L) 850 V(DC+ACpeak)(CAT I and II, 600 Vrms). DC offset range (max) (At 1:1 probe attenuation): 5 mV/div to 50 mV/div : ± 0.5 V, 100 mV/div to 500 mV/div : ± 5 V, 1 V/div to 5 V/div : ± 50 V, 10 V/div to 20 V/div : ± 250 V. Input connector: BNC connector (isolating type). Input impedance: 1 M-ohm 1%, approx. 30pF. -3dB point for AC coupling used: 10 Hz or less(1 Hz or less when using 700929). Common mode rejection ratio: 80 dB(50/60 Hz) or more (typica). Residual noise: Larger of ± 400 mV or ± 0.06 div(typical). Withstand voltage (across input terminal and earth): 3700 VAC for 1 minute (60 Hz). Probe attenuation settings: 1:1, 10:1, 100:1 and 1000:1. Bandwidth limit: Select from OFF/500 Hz/5 kHz/ 50 kHz/ 500 kHz.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701855. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your YOKOGAWA 701855 CALIBRATION and/or YOKOGAWA 701855 High-Speed 10 Ms/s 12-Bit Isolation Module REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: