Keysight (Agilent) B2901A CALIBRATION and Keysight (Agilent) B2901A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) B2901A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) B2901A   Description / Specification:    
Keysight (Agilent) B2901A Single Ch Precision Source/Measure Unit

The Keysight / Agilent B2901A Single Channel Precision Source/Measure Unit is a compact and cost-effective bench-top Source/Measure Unit (SMU) with the capability to source and measure both voltage and current. These capabilities make the B2901A ideal for a wide variety of IV (current versus voltage) measurement tasks that require both high resolution and accuracy.
Specifications.

Voltage source specifications.
Range, Programming resolution, Accuracy (% reading + offset), Noise (pk to pk)0.1 Hz to 10 Hz, Max voltage.
  ±200 mV, 1 μV, ±(0.015 % + 225 μV), ≤ 10 μV, ±210 mV.
  ±2 V, 10 μV, ±(0.02 % + 350 μV), ≤ 20 μV, ±2.1 V.
  ±20 V, 100 μV, ±(0.015 % + 5 mV), ≤ 200 μV, ±21 V.
  ±200 V, 1 mV, ±(0.015 % + 50 mV), ≤ 2 mV, ±210 V.

Current source specifications.
Range, Programming resolution, Accuracy (% reading + offset), Noise (pk to pk)0.1 Hz to 10 Hz, Max current.
  ±100 nA, 1 pA, ±(0.06 % + 100 pA), ≤ 2 pA, ±105 nA.
  ±1 μA, 10 pA, ±(0.025 % + 500 pA), ≤ 25 pA, ±1.05 μA.
  ±10 μA, 100 pA, ±(0.025 % + 1.5 nA), ≤ 60 pA, ±10.5 μA.
  ±100 μA, 1 nA, ±(0.02 % + 25 nA), ≤ 2 nA, ±105 μA.
  ±1 mA, 10 nA, ±(0.02 % + 200 nA), ≤ 6 nA, ±1.05 mA.
  ±10 mA, 100 nA, ±(0.02 % + 2.5 μA), ≤ 200 nA, ±10.5 mA.
  ±100 mA, 1 μA, ±(0.02 % + 20 μA), ≤ 600 nA, ±105 mA.
  ±1 A, 10 μA, ±(0.03 % + 1.5 mA), ≤ 70 μA, ±1.05 A.
  ±1.5 A, 10 μA, ±(0.05 % + 3.5 mA), ≤ 100 μA, ±1.515 A.
  ±3 A, 100 μA, ±(0.4 % + 7 mA), ≤ 120 μA, ±3.03 A.
  ±10 A pulse mode only, 100 μA, ±(0.4 % + 25 mA), , ±10.5 A.

Maximum current limitation
  ±(0 V < V ≤ 6 V) ≤ 4 A ,
  ±(6 V < V ≤ 21 V) ≤ 2.5 A.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your Keysight (Agilent) B2901A CALIBRATION and/or Keysight (Agilent) B2901A Single Ch Precision Source/Measure Unit REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: