Keysight (Agilent) DSOX3054A CALIBRATION and Keysight (Agilent) DSOX3054A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSOX3054A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSOX3054A (DSO-X3054A)   Description / Specification:   Spec Sheet 
Keysight (Agilent) DSOX3054A 4 Ch 500 MHz InfiniiVision Oscilloscope

The Agilent DSOX3054A X-Series’s Oscilloscope innovation starts with 5-instruments-in-1 integration. The one million waveforms per second update rate is 20 times faster than the competition to display the most signal detail. The 3000 X-Series provides maximum investment protection with fully-upgradable 5-instruments-in-1; even bandwidth is upgradable. The InfiniiVision DSOX3054A X-Series comes with a large 8.5-inch WVGA display so you can view analog, digital and serial signals easily on the screen. With up to 4 Mpts of MegaZoom IV deep memory, you can capture long, non-repeating signals while maintaining a high sample rate, then quickly zoom in on areas of interest. Upgrade the DSOX3054A yourself to an MSO with a license to turn on those integrated 16 digital channels.

Specifications.

Analog Bandwidth (- 3 dB): 500 MHz.
Analog Input channels: 4.
Calculated rise time (10-90%): <= 800 ps.

Hardware bandwidth limits: Approximately 20 MHz (selectable).
Input coupling: AC, DC.
Input impedance Selectable: Selectable: 1 MΩ ± 1%; 50 Ω ± 1.5%
Sample rate on each channel: 2 GSa/s per channel, 4 GSa/s interleaved.
Memory depth (record length): Up to 4 Mpts.
Display: 8.5-inch WVGA with 64 levels of intensity grading.
Waveform update rate (max): 1,000,000 waveforms/s.
Vertical resolution: 8 bits.
Horizontal resolution: 2.5 ps.
Maximum input voltage: 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk, With N2862A, N2863A or N2890A 10:1 probe: 300 Vrms.
DC vertical accuracy: ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale].
DC vertical gain accuracy: ± 2.0% full scale.
Offset range: ±2 V (2 mV/div to 200 mV/div), ±50 V (> 200 mV/div to 5 V/div).
DC vertical offset accuracy: ±0.1div ± 2mV ± 1% of offset setting.

Horizontal system analog channels.
Maximum sample rate: 4 GSa/s half channel, 2 GSa/s all channel.
Maximum memory depth: Standard 2 Mpts, optional 4 Mpts and optional segment memory.
Waveform update rate: > 1 million waveforms per second.
Time base range: 1 ns/div to 50 s/div.
Channel-to-channel deskew range: ± 100 ns.
Time base accuracy: 25 ppm ± 5 ppm per year (aging).
Delta Time accuracy (using cursors): ± (time base acc. x reading) ± (0.0016 x screen width) ± 100 ps.



 

Standard Calibration $460.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSOX3054A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) DSOX3054A CALIBRATION and/or Keysight (Agilent) DSOX3054A 4 Ch 500 MHz InfiniiVision Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: