A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS MM560A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS MM560A   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS MM560A MultiMaster True RMS High-Accuracy Multimeter

The Extech MM560A MultiMaster True RMS High-Accuracy Multimeter features special True RMS combination AC+DC function for measurements of rectified AC (non-symmetrical) voltage & current waveforms. Filtered frequency function with adjustable trigger levels for variable speed motor drives and high voltage applications. 50,000 count (500,000 for DCV and Hz) backlit LCD display with bargraph. Max/Min recording with autoranging, Auto Power off, Relative & Hold, Peak function captures transient pulses. Specifications. AC Voltage Ranges: 500mV, 5V, 50V, 500V, 1000V. AC Voltage Maximum Resolution: 0.01 mV. AC Voltage Basic Accuracy (%rdg+digits): ±(0.8% + 60d). DC Voltage Ranges: 500mV, 5V, 50V, 500V, 1000V. DC Voltage Maximum Resolution: 0.01 mV. DC Voltage Basic Accuracy (%rdg+digits): ±(0.03% + 2d). AC Current Ranges: 500µA, 5000µA, 50mA, 500mA, 5A, 10A. AC Current Maximum Resolution: 0.01 µA. AC Current Basic Accuracy (%rdg+digits): ±(1% + 40d). DC Current Ranges: 500µA, 5000µA, 50mA, 500mA, 5A, 10A. DC Current Maximum Resolution: 0.01 µA. DC Current Basic Accuracy (%rdg+digits): ±(0.1% + 20d). Resistance Ranges: 500, 5k, 50k, 500k, 5M, 50Mohm. Resistance Maximum Resolution: 0.01 ohm. Resistance Basic Accuracy (%rdg+digits): ±(0.1% + 6d). Capacitance Ranges: 50 nF to 9999 µF. Capacitance Maximum Resolution: 0.01 nF. Capacitance Basic Accuracy (%rdg+digits): ±(0.8% + 3d). Line Frequency Ranges: 5 Hz to 200 kHz. Line Frequency Maximum Resolution: 0.0001 Hz. Line Frequency Basic Accuracy (%rdg+digits): ±(0.002%+4d). Logic Frequency Ranges: 5 Hz to 200 kHz. Logic Frequency Maximum Resolution: 0.0001 Hz. Logic Frequency Basic Accuracy (%rdg+digits): ±(0.002%+4d). Duty Cycle: 0.1% to 99.99%. Duty Cycle Maximum Resolution: 0.01%. Duty Cycle Basic Accuracy: ±(3d/kHz + 2d).



 

Standard Calibration $180.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS MM560A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your EXTECH INSTRUMENTS MM560A CALIBRATION and/or EXTECH INSTRUMENTS MM560A MultiMaster True RMS High-Accuracy Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: