Keysight (Agilent) MSO9254A CALIBRATION and Keysight (Agilent) MSO9254A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) MSO9254A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) MSO9254A   Description / Specification:    
Keysight (Agilent) MSO9254A 4+16 Ch 2.5 GHz Mixed Signal Infiniium Oscilloscope

The Agilent MSO9254A Infiniium 2.5 GHz, 4 analog plus 16 digital channels is equipped with a 15” XGA display and comes in a package that is just 9” (23 cm) deep and weighs only 26 pounds (11.8 kg) to preserve your limited bench space. This scope is engineered to give you the broadest measurement capability available to meet your needs both today and in the future. 16 fully integrated, time-aligned digital channels give you insight into timing relationships and allow precise triggering. Take advantage of optional integrated protocol viewers to quickly isolate physical layer issues causing errors. Analog bandwidth (–3 dB) 50 ohm: 2.5 GHz. Typical Rise Time / Fall Time 10% to 90% at 50 ohm: 142 ps. Typical Rise Time / Fall Time 20% to 80% at 50 ohm: 98 ps. Input channels: 4 analog + 16 digital. Input impedance: 50 ohm ± 2.5%, 1 Mohm ± 1% (11pF typical). Input sensitivity: 1 Mohm: 1 mV/div to 5 V/div, 50 ohm: 1 mV/div to 1 V/div. Bandwidth limit: 20 MHz on 1 Mohm input ; 500 MHz up to full scope bandwidth in increments of 500 MHz. Vertical resolution: 8 bits, =12 bits with averaging. DC gain accuracy: ± 2% of full scale at full resolution on channel scale ± 5 °C from cal temp. Maximum input voltage: 1 Mohm: 150V RMS or DC, CAT I ± 250 V (DC + AC) in AC coupling, 50 ohm: 5 Vrms. Digital Channels; Input channels: 16 digital channels. Threshold groupings: 16 digital channels Pod 2, D15 – D8. Threshold selections: TTL (1.4V), CMOS, (5.0V, 3.3V, 2.5V), ECL (-1.3V), PECL (3.7V), user defined (±8.00 V in 100 mV increments). Maximum input voltage: ±40 V peak CAT I. Threshold accuracy: ±(100 mV + 3% of threshold setting). Input dynamic range: ±10 V about threshold. Minimum input voltage swing: 500 mV peak-to-peak. Input impedance (flying leads): 100 kohm ± 2% (~ 8 pF) at probe tip. Resolution: 1 bit. Analog bandwidth: 400 MHz. Horizontal; Channel-to-channel skew (digital): 2 ns typical. Glitch detect (digital): >= 2.0 ns. Main time base range: 5 ps/div to 20 s/div. Horizontal position range: 0 to ± 200 s. Delayed sweep range: 1 ps/div to current main time base setting. Resolution: 1 ps. Modes: Main, delayed, roll (200 ms to 20 sec). Maximum real-time sample rate: 4 ch x 10 GS/s or 2 ch x 20 GS/s. Option 50M, 50 Mpts on 4 channels, 100 Mpts on 2 channels. Option 100, 100 Mpts on 4 channels, 200 Mpts on 2 channels. Option 200, 200 Mpts on 4 channels, 400 Mpts on 2 channels. Option 500, 500 Mpts/ 250 Mpts on 4 channels, 1 Gpts/ 500 Mpts on 2 channels (single/repetitive mode).



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) MSO9254A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) MSO9254A CALIBRATION and/or Keysight (Agilent) MSO9254A 4+16 Ch 2.5 GHz Mixed Signal Infiniium Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: