A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SORENSEN DCR300-1.5B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   SORENSEN DCR300-1.5B   Description / Specification:    
SORENSEN DCR300-1.5B 300V 1.5A Single Output DC Power Supply

The Sorenson DCR300-1.5B Power Supply incorporates a single phase input SCR controlled regulator providing high efficiency and fully adjustable output power. It has excellent voltage and current regulation with automatic crossover. Features. Panel lights indicate operating mode. Remote voltage and resistance programming in voltage and current modes. Adjustable current limiting (overload/short circuit protection) with automatic recovery. Overvoltage protection standard. Specifications. Output Voltage: 0 to 300 Vdc. Output Current (40 C): 1.5 A. Constant Voltage Regulation: 150 mV. Constant Current Regulation: 4 mA. Constant Voltage Ripple (PARD): 700 rms/mV. Constant Current Ripple (PARD): 4 rms/mA. Voltage Regulation (Constant Voltage Mode): 0.05% or 75 mV, whichever is greater. Temperature Coefficient: 0.015%/C of Eo max. Stability: 0.1% Eo max for 8 hours after 30 minute warm-up. Remote Sensing: Maximum drop per load lead should not exceed 5% of Eo max. or 3 V, whichever is smaller. Transient Response: 50 ms (typical) to return to ± 1% band for step load change of 50 to 100% of full load. Current Regulation (Constant Current Mode): 0.25% of 10 max. line and load combined. Temperature Coefficient: 0.03%/C. of lo max. Stability: 0.15% of 10 max. for 8 hours after 30 minute warm-up.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the SORENSEN DCR300-1.5B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your SORENSEN DCR300-1.5B CALIBRATION and/or SORENSEN DCR300-1.5B 300V 1.5A Single Output DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: