SLAUGHTER 2630 CALIBRATION and SLAUGHTER 2630 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SLAUGHTER 2630 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   SLAUGHTER 2630   Description / Specification:    
SLAUGHTER 2630 30A AC Ground Bond Tester

The Slaughter 2630 is an enhanced Ground Bond tester that is a companion instrument to the 2900 series. Whether used with the 2900 series as a system or as a stand alone instrument, the 2630 is equipped with the technology and features which make it a perfect choice for production line safety testing. It features Milliohm Offset Capability that minimizes the effect of test lead resistance or resistance of test fixturing. The milliohm offset function allows the resistance of longer test leads and test fixtures to be subtracted from the test results.

Specifications

Output
Current: AC 3 - 30 Amps, 0.1 Amp/step
Regulation: ± (2% of Setting + 0.02A)
Voltage: AC 6 Volts fixed

Output Frequency: 50/60 Hz user selectable

Dwell Time Setting
0 and 0.5 - 999.9 seconds, 0.1 second/step
0 for continuous running
Accuracy: ± (0.1% of Setting + 0.05 seconds)

Failure Settings
High limit: 0 - 120mΩ for 10 - 30 Amps, 1mΩ/step
0 - 510mÙ for 10 Amps, 1mÙ/step
Accuracy: ± (2% of setting + 2mΩ)

Milliohm Offset
Capability: 100mΩ, 1mΩ/step
Accuracy: ± (2% of setting + 2mΩ)

Metering
Ammeter (3 digits)
Range: 0 - 30 Amps
Resolution: 0.1 Amp/step
Accuracy: ± (3% of Reading + 0.03A)
Ohmmeter (3 digits)
Range: 0 - 510mΩ
Resolution: 1 mΩ/step
Accuracy: + (2% of Reading +2mΩ)
Timer (4 digits)
Range: 0 - 999.9 seconds
Resolution: 0.1 seconds/step
Accuracy: ± (0.1% of Reading + 0.05 seconds)



 

Standard Calibration $635.00 *
*This is a Web introductory price for one calibration of the SLAUGHTER 2630. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your SLAUGHTER 2630 CALIBRATION and/or SLAUGHTER 2630 30A AC Ground Bond Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.