Keysight (Agilent) DSAX92804A CALIBRATION and Keysight (Agilent) DSAX92804A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSAX92804A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSAX92804A (DSA-X92804A)   Description / Specification:   Spec Sheet 
Keysight (Agilent) DSAX92804A 4 Ch 28 GHz Infiniium Oscilloscope / Signal Analyzer

The Agilent Infiniium DSAX92804A 4 Ch 28 GHz Infiniium Oscilloscope / Signal Analyzer is engineered for 33 GHz true analog bandwidth that delivers. It comes with more than 15 protocol decoders, including the industry's only 64/66b decoder. The 90000 X-Series protocol tools feature time-correlated markers that let you easily move between the listing window and the waveform. Protocol tools can be used on up to four lanes simultaneously. A 10 MHz reference clock can be input to or output from the scope to allow precise timebase synchronization with more than one oscilloscope, RF instruments or logic analyzers. Serial data equalization for the 90000 X-Series provides fast and accurate equalization using decision feedback equalization (DFE), feed-forward equalization (FFE), and continuous time linear equalization (CTLE) modeling in real time. Serial data equalization software allows you to input your own self-designated tap values to verify your design. Performance characteristics. Analog bandwidth (-3 dB): 28 GHz (2 channel), 16 GHz (4 channel). Rise time/fall time: 14.4 ps (10 - 90%), 11 ps (20 - 80%). Input impedance: 50 ohm, ± 3%. Sensitivity: 1 mV/div to 1 V/div. Input coupling: DC. Vertical resolution: 8 bits, >= 12 bits with averaging. DC gain accuracy: ± 2% of full scale at full resolution channel scale (± 2.5% for 5mV/div). Maximum input voltage: ± 5 V. Dynamic range: ± 4 div from center screen. RMS noise floor (scope only): 0.53 V (Volts/div, 10 mV), 36.57 V (Volts/div, 1 V). Main timebase range: 2 ps/div to 20 s/div real-time. Main timebase delay range: -200 s to 200 s real-time. Zoom timebase range: 1 ps/div to current main time scale setting. Channel deskew: ±1 ms range, 10 fs resolution. Time scale accuracy: ± [0.1 ppm (immediately after calibration) ±0.1 ppm/year (aging)]. Maximum real-time sample rate: 40 GSa/s (4 channels simultaneously), 80 GSa/s (2 channels simultaneously). Memory depth per channel Standard: 50 Mpts on 4 channels, 100 Mpts on 2 channels. Display: 12.1-inch color XGA TFT-LCD with touch screen. The DSAX92804A comes with standard 50 Mpts memory, EZJIT, EZJIT+, EZJIT Complete, and Serial Data Analysis standard.



 

Standard Calibration $865.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSAX92804A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) DSAX92804A CALIBRATION and/or Keysight (Agilent) DSAX92804A 4 Ch 28 GHz Infiniium Oscilloscope / Signal Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: