Keysight (Agilent) N5106A CALIBRATION and Keysight (Agilent) N5106A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N5106A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) N5106A   Description / Specification:    
Keysight (Agilent) N5106A PXB Baseband Generator and Channel Emulator

The Agilent N5106A PXB Baseband Generator and Channel Emulator supports multiple functions, future technologies, frequent use and easy upgrades. You can leverage one multipurpose diagnostic toolset across the R&D lifecycle: design, integration, verification and pre-conformance. The N5106A PXB lets you model the signal-propagation environment with fully parameterized real-time channel emulation (fading). With the largest playback memory available, you can run longer test sequences to better approximate real-world signals. You can also capture signals up to 512 Msa from your own device for post-processing. Up to 160 MHz modulation and signal capture bandwidth. Up to 6 BBGs and 16 faders for interference, diversity and MIMO test. Characteristics. Number of baseband generators: Up to 6. PXB Analog I/Q outputs: 160 MHz. Arbitrary waveform memory: 512 Msa (2 GB) per baseband generator. Sample rate: 1 kSa/sec to 150 MSa/sec. Resolution: 14 bits. Baseband frequency offset range: –80 MHz to 80 MHz. Waveform length: 256 samples to 512 Msa. Number of Digital I/O ports: 2 per I/O card, up to 8 total. Resolution: 14 bits. Baseband frequency offset: –80 MHz to 80 MHz. Analog Output Port type: Analog I/Q, single-ended and differential. Level: 1.0 Vpp single-ended, 2.0 Vpp differential; 50 ohm. Resolution: 14 bits. Baseband frequency offset: –80 MHz to 80 MHz. Available chassis slots: Up to 6 baseband cards (or 12 DSP blocks) and up to 4 I/O cards. Connectivity: Gigabit LAN, IEEE 488 GPIB. Option Bundles. 2B2 - 2x2 MIMO bundle. 2B4 - 2x4 MIMO bundle. 4B2 - 4x2 MIMO bundle. 185 - Global navigation satellite system application bundle. 186 - Digital video application bundle.



 

Functional Test $185.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N5106A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) N5106A CALIBRATION and/or Keysight (Agilent) N5106A PXB Baseband Generator and Channel Emulator REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: