ANRITSU S331L CALIBRATION and ANRITSU S331L REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU S331L Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Cellular Test Set?
Shop for Comparable Products on our
 used Cellular Test Set page or new Cellular Test Set page

 
   ANRITSU S331L   Description / Specification:   Spec Sheet 
ANRITSU S331L 4 GHz Site Master Handheld Cable & Antenna Analyzer

The Anritsu S331L Site Master Handheld Cable & Antenna Analyzer replaces the current value line S331D which is part of the longest running portable cable and antenna analyzer family in history. Utilizing the latest advancements in technology, the S331L has been optimized for field conditions, is easy to use, and has efficient sweep management capabilities. The S331L delivers an entire workday of battery operating time, the most ever offered in a handheld cable and antenna analyzer. With its large outdoor viewable 7" TFT touch screen display, new intuitive GUI, and classic mode that mimic the S331D basic measurement flow, the S331L is very easy to use, and can significantly increase a user’s efficiency in the field.
Specifications

Cable & Antenna Analyzer
Frequency Range: 2 MHz to 4 GHz.
Frequency Accuracy: <= ± 5 ppm @ 25 °C.
Frequency Resolution: 1 kHz.
Return Loss: <= 1.50 ms/data point, RF immunity low, typical.
Distance-to-Fault: <= 1.75 ms/data point, RF immunity low, typical.
Interference Immunity On-Channel: +17 dBm outside calibrated sweep range.
Interference Immunity On-Frequency: +13 dBm within calibrated sweep range.

Internal Power Meter
Frequency Range: 50 MHz to 4 GHz.
Display Range: -100 dBm to +100 dBm.
Measurement Range: -33 dBm to +20 dBm.
Offset Range Max: ± 100 dB, user settable value.

General
Measurements: Return Loss, VSWR, Cable Loss, Distance-to-Fault RL, Distance-to-Fault VSWR, RF Power.
Internal Trace Storage: > 1000 files (files may be traces, setups, screen shots, or any combination).
External Trace Storage: Limited only by size of USB Flash drive.
Connectivity: (2) USB 2.0 Type A, Interface: Type mini-B, Connect to PC for data transfer.
Display: TFT Resistive Touch Screen, 7.0” daylight viewable color LCD, 800 x 480 resolution.



 

Standard Calibration $465.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU S331L. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Decibel (dB)
A unit of measurement of optical power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

PDH
Plesiochronous Digital Hierarchy (PDH) is a transmission system for voice communication using plesiochronous synchronisation. The transmitter adds dummy information bits to allow multiple channels to be bit interleaved. The receiver discards these bits once the signals have been demultiplexed. PDH combines multiple 2 Mb/s (E1) channels in Europe and 1.544 Mb/s (DS1) channels in the US and Japan.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).


Please contact us for your ANRITSU S331L CALIBRATION and/or ANRITSU S331L 4 GHz Site Master Handheld Cable & Antenna Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: