Keysight (Agilent) N8482A CALIBRATION and Keysight (Agilent) N8482A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N8482A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   Keysight (Agilent) N8482A   Description / Specification:   Spec Sheet 
Keysight (Agilent) N8482A 6 GHz Thermocouple Power Sensor

The Agilent N8482A Thermocouple Power Sensor is the replacement solution for 8480 Series Power Sensors. The new power sensor is integrated with EEPROM feature, which allows users to calibrate the power sensors without manually entering the calibration factors to the power meter. By comparing to legacy 8480 Series Power Sensors, there are tremendous improvements such as wider dynamic range and frequency range, better accuracy, linearity, repeatability, and SWR. Specifications. Frequency range: 100 kHz to 6 GHz. Dynamic power range: -35 to +20 dBm. Damage level (average power): +25 dBm. Damage level (peak power): 15 W/2 µs. Maximum SWR 25 °C ± 10 °C: 1.54 (100 to 300 kHz), 1.17 (300 kHz to 1 MHz), 1.06 (1 MHz to 2 GHz), 1.07 (2 to 6 GHz). Linearity (25 °C ± 10 °C): ±0.52% (–1 to < +15 dBm), ±0.80% (+15 to +20 dBm). Connector: N-type (male). Option CFT, N8482A sensor without the calibration factor table stored in the EEPROM.



 

Standard Calibration $270.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N8482A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) N8482A CALIBRATION and/or Keysight (Agilent) N8482A 6 GHz Thermocouple Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: