Keysight (Agilent) U1232A CALIBRATION and Keysight (Agilent) U1232A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) U1232A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   Keysight (Agilent) U1232A   Description / Specification:   Spec Sheet 
Keysight (Agilent) U1232A True RMS 6000 Count Handheld Digital Multimeter

The Agilent U1232A True RMS 6000 Count Handheld Digital Multimeter is equipped with features that anticipate worstcase scenarios. The ergonomic shaped handheld allows you to single-handedly illuminate the test area with a built-in flashlight while selecting measurement functions using the rotary dial. Its audible beep and flashing backlight display provides increased visual and audio alert to indicate continuity. Specifications. DC Voltage Ranges: 600 mV (Resolution 0.1 mV) to 600V (Resolution 0.1 V). Resistance Ranges: 600 ohm (Resolution 0.1 ohm) to 60 M-ohm (Resolution 0.01 M-ohm). Diode Range: 2 V (Resolution 0.001 V). DC Current Ranges: 60 µA (Resolution 0.01 µA) to 10 A (Resolution 0.01 A). AC Voltage Ranges: 600 mV (Resolution 0.1 mV) to 600V (Resolution 0.1 V). AC Current Ranges: 60 µA (Resolution 0.01 µA) to 10 A (Resolution 0.01 A). Capacitance Ranges: 1000 nF (Resolution 1 nF) to 10 mF (Resolution 0.01 mF). Temperature Thermal type K Ranges: -40 °C to 1372 °C and -40 °F to 2502 °F. Frequency Ranges: 99.99 Hz (Resolution 0.01 Hz) to 99.99 kHz (Resolution 10 Hz). Display: Liquid crystal display (LCD) (with maximum reading of 6600 counts). Flashlight: Cool white LED (5500 K typical); luminous intensity from 2240 mcd to 5600 mcd. Data logging capability (stores up to 10 readings). Compatible with U1177A IR-Bluetooth adapter for remote monitoring & datalogging.



 

Standard Calibration $60.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) U1232A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) U1232A CALIBRATION and/or Keysight (Agilent) U1232A True RMS 6000 Count Handheld Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: