A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) U1233A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   Keysight (Agilent) U1233A   Description / Specification:   Spec Sheet 
Keysight (Agilent) U1233A True RMS 6000 Count Handheld Digital Multimeter

The Agilent U1233A True RMS 6000 Count Handheld Digital Multimeter with non-contact voltage detector is equipped with features that anticipate worstcase scenarios. The ergonomic shaped handheld allows you to single-handedly illuminate the test area with a built-in flashlight while selecting measurement functions using the rotary dial. Its audible beep and flashing backlight display provides increased visual and audio alert to indicate continuity. The U1233A includes Vsense, it performs non-contact voltage detection while continuity detection is made easy with the audible beeper alert and flashing backlight display. Specifications. DC Voltage Ranges: 600 mV (Resolution 0.1 mV) to 600V (Resolution 0.1 V). Resistance Ranges: 600 ohm (Resolution 0.1 ohm) to 60 M-ohm (Resolution 0.01 M-ohm). Diode Range: 2 V (Resolution 0.001 V). DC Current Ranges: 60 µA (Resolution 0.01 µA) to 10 A (Resolution 0.01 A). AC Voltage Ranges: 600 mV (Resolution 0.1 mV) to 600V (Resolution 0.1 V). AC Current Ranges: 60 µA (Resolution 0.01 µA) to 10 A (Resolution 0.01 A). Capacitance Ranges: 1000 nF (Resolution 1 nF) to 10 mF (Resolution 0.01 mF). Temperature Thermal type K Ranges: -40 °C to 1372 °C and -40 °F to 2502 °F. Frequency Ranges: 99.99 Hz (Resolution 0.01 Hz) to 99.99 kHz (Resolution 10 Hz). Display: Liquid crystal display (LCD) (with maximum reading of 6600 counts). Flashlight: Cool white LED (5500 K typical); luminous intensity from 2240 mcd to 5600 mcd. Data logging capability (stores up to 10 readings). Compatible with U1177A IR-Bluetooth adapter for remote monitoring & datalogging.



 

Standard Calibration $105.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) U1233A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) U1233A CALIBRATION and/or Keysight (Agilent) U1233A True RMS 6000 Count Handheld Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: