AEMC 511 CALIBRATION and AEMC 511 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC 511 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC 511 (2117.67)   Description / Specification:   Spec Sheet 
AEMC 511 1000 Amp AC/DC Clamp-On Meter

The AEMC 511 AC Clamp-on Meter is a full function meter with a high resolution 40A range that can measure continuity, resistance to 4000O, volts 750VAC/1000DC, frequency (V or A) & current (1000AAC). This auto-ranging clamp meter is buit into a rugged mechanical case & is in compliance with international safety and quality standards. TheAEMC 511 Current Clamp-on Meter features a jaw opening of 1.575". Specifications. AC Current (Auto-Ranging): 0.05 to 1000 A. AC Current Resolution: 0.01A, 0.1A and 1A. AC Voltage (Auto-Ranging): 0.5 to 750 V. AC Voltage Resolution: 0.1 V and 1 V. AC Voltage Input Impedance: 10 Mohm. DC Voltage (Auto-Ranging): 0.2 to 1000V. DC Voltage Resolution: 0.1 V and 1 V. DC Voltage Input Impedance: 10 Mohm. Resistance: 0.2 to 4000 ohm. Resistance Accuracy: 1% of Reading ± 2 cts. Resistance Max Test Voltage: 3 VDC. Diode Test: 0.6 mA. Continuity: <40 ohm. Frequency (Auto-Ranging): 4 kHz (1 Hz Resolution). Frequency Accuracy 20Hz to 10kHz: 0.1% of Reading ± 1 ct.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC 511. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your AEMC 511 CALIBRATION and/or AEMC 511 1000 Amp AC/DC Clamp-On Meter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: