Keysight (Agilent) 33120A REPAIR and Keysight (Agilent) 33120A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 33120A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 33120A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) 33120A   Description / Specification:    
Keysight (Agilent) 33120A Function/Arbitrary Waveform Generator

The Agilent 33120A is a function and arbitrary waveform generator. It is capable of producing Sine, square, triangle, ramp, noise, sin(x)/x, exponential rise, exponential fall, heartbeat and dc volts. Its arbitrary waveform generator is capable of handling waveform lengths from 8 to 16,000 points, with an amplitude resolution of 12 bits (including sign), with a sample rate of 40 MSa/s. Sine and square waves can be produced at frequencies from 100 micro-hertz to 15 MHz. Triangle and ramp wave forms can be produced at frequencies from 100 micro-hertz to 100 kHz, while noise can be generated in a 10 MHz bandwidth. Frequency resolution is as high as 10 micro-hertz or 10 digits. Wave form frequency is accurate to 10 ppm for 90 days, and to 20 ppm for 1 year. Sine waveforms have harmonic distortion at -70 dBc at frequencies from DC to 20 kHz, at -60 dBc from 20 kHz to 100 kHz, at -45 dBc from 100 kHz to 1 MHz, and at -35 dBc from 1 MHz to 15 MHz. Spurious distortion occurs at frequencies from DC to 1 MHz at levels below -65 dBc. For all other frequencies, it occurs below -65 dBc plus 6 dB per octave. Phase noise occurs below -55 dBc in a 30 kHz band. Generated square waves have rise/fall times under 20 ns and less than 4% overshoot. Square wave asymmetry is <1% plus 5 ns. Available duty cycles include 20% to 80% for frequencies up to 5 MHz, and 40% to 60% up to 15 MHz. For triangle, ramp, and arbitrary wave forms, typical rise/fall times are 40 ns. The settling time is <250 ns to be within 0.5% of the final value, with a jitter under 25 ns. The output level can range from 50 mV p-p to 10 V p-p. Level settings are accurate within 1% at frequencies of 1 kHz. The average flatness across all output frequencies is within 2% of level setting. Offset is adjustable across +/-5Vpk + dc, accurate within +/-2% of the setting + 2 mV. # digits of resolution are available for both amplitude and offset, with readings displayed in V pp, V rms, and dBm. AM is provided across all waveforms including arbitrary, with frequencies up to 20 kHz both internaly and externaly. FM is provided for all waveforms as well to frequencies of 10 kHz. FM peak deviation is 10 mHz to 15 MHz. Only internal FM is provided. FSK is available with internal rates from 10 mHz to 50 kHz, and a frequency range from 10 mHz to 15 MHz. Both internal and external sources are available, with external sources up to 1 MHz. Burst modulation has a maximum carrier frequency of 5 MHz, with cycle counts from 1 to 50,000 cycles or infinite. The phase can be set from -360 to 360 degrees. The internal rate for burst mod is 10 mHz to 50 kHz +/-1%. Burst mod can be gated both internally and externally. The 33120A can make linear or logorithmic sweeps up or down, with start and stop frequencies that can fall within 10 mHz to 15 MHz. Sweep speeds can be 1 ms to 500 s +/- 0.1%. Sweep triggers can be internal, external or single. Additional features include a state storage memory which stores the off state on power-down. The exteranl clock reference is stable within +/-1 ppm from 0 to 50 degrees C, with an aging rate under 2ppm after 30 days of continuous operation and 0.1 ppm/month after the first 30 days.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 33120A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your Keysight (Agilent) 33120A REPAIR and/or Keysight (Agilent) 33120A Function/Arbitrary Waveform Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: