AMPROBE AM-560 CALIBRATION and AMPROBE AM-560 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE AM-560 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   AMPROBE AM-560   Description / Specification:    
AMPROBE AM-560 Advanced HVAC Multimeter

The Amprobe AM-560 Advanced HVAC Multimeter is specifically designed for the more demanding HVAC applications. The AM-560 measures a complete range of electrical parameters and key functions such as dual thermocouples for taking differential temperature measurements, low pass filter to take accurate measurements on variable frequency drives and capacitance to check motor startup capacitors. It also features micro amps for flame sensor troubleshooting, and a complete range of electrical parameters. With built-in flashlight and VolTect ™ non-contact voltage detection. Specifications. AC Voltage Ranges: 6.000 / 60.00 / 600.0 / 1000 V. AC Voltage Best Accuracy: ±(1.0% Rdg + 3 LSD) @ 45 Hz to 400 Hz, 0 V to 600 V. DC Voltage Ranges: 600.0 mV / 6.000 / 60.00 / 600.0 / 1000 V. DC Voltage Best Accuracy: ±(0.5% Rdg + 2 LSD) @ 6 V to 600 V ranges. Resistance Ranges: 600.0 Ohms / 6.000 / 60.00 / 600.0 kOhms / 6.000 / 60.00 MOhms. Resistance Best Accuracy: ±(1.0% Rdg + 2 LSD) @ 6 kOhms to 600 kOhms ranges. AC Current Ranges: 600.0 µA / 6000 µA / 60.00 mA / 500.0 mA / 10.00 A. AC Current Best Accuracy: ±(1.2% Rdg + 5 LSD) @ 600 µA to 6000 µA ranges, 45 Hz to 400 Hz. DC Current Ranges: 600.0 µA / 6000 µA / 60.00 mA / 500.0 mA / 10.00 A. DC Current Best Accuracy: ±(1.0% Rdg + 2 LSD) @ 600 µA to 6000 µA ranges. Frequency Ranges: 60.00 / 600.0 Hz / 6.000 / 60.00 / 600.0 kHz / 6.000 / 60.00 MHz. Frequency Best Accuracy: ±(0.1% Rdg + 3 LSD). Capacitance Ranges: 60.00 / 600.0 nF / 6.000 / 60.00 / 600.0 / 6000 µF / 60.00 mF. Capacitance Best Accuracy: ±(3.0% Rdg + 5 LSD) @ 600 nF to 60 µF ranges. Duty Cycle: 10.00% to 90.00%. Duty Cycle Best Accuracy: ±(1.2% Rdg + 30 LSD) @ 5Hz to 2 kHz. Temperature Ranges: -40 °F to 1832 °F / -40 °C to 1000 °C. Temperature Best Accuracy: °F: ±(1.0% rdg + 12) @ >104 °F to 752 °F / °C: ±(1.0% rdg + 8) @ >40 °C to 400 °C. Safety rated: CAT IV 600V, CAT III 1000V. Dual reading backlit LCD display with analog bar graph.



 

Standard Calibration $185.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE AM-560. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your AMPROBE AM-560 CALIBRATION and/or AMPROBE AM-560 Advanced HVAC Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: