The Amprobe AC68C True-rms 600A Clamp Meter measures non-linear load current with true-rms readings. Specifications. DC Voltage Ranges: 600 V. DC Voltage Accuracy: ± (0.75 % rdg + 2 dgts). DC Voltage Resolution: 1 V in 600 V range. AC Voltage (40-450 Hz) Ranges: 400 V, 600 V. AC Voltage Accuracy: ± (1.2 % rdg + 5 dgts). AC Voltage Resolution: 0.1 V in 400 V range. DC Current Ranges: 400 A, 600 A. DC Current Accuracy: ± (2 % rdg + 5 dgts). DC Current Resolution: 0.1 A in 400 A range. AC Current (40-450 Hz) Ranges: 400 A, 600 A. AC Current Accuracy: ± (2 % rdg + 5 dgts). AC Current Resolution: 0.1 A in 400 A range. Frequency (Hz), Current and Voltage Ranges: 4 kHz, 20 kHz. Frequency (Hz) Accuracy: ± (0.5 % rdg + 5 dgts). Frequency (Hz) Resolution: 1 Hz in 4 kHz range. Resistance Range: 4 kohm. Resistance Accuracy: ± ( 1.0 % rdg + 5 dgts). Resistance Resolution: 1 ohm in 4 kohm range. Diode Test Accuracy: ± (1.0 % rdg + 2 dgts). Diode Test Resolution: 0.001 V. Continuity Range Threshold: Tone at 40 ohm ± 15 ohm. Peak Hold Measurement AC Voltage (40-450 Hz) Ranges: 400 V, 600 V. Peak Hold Measurement AC Voltage Accuracy: ± (1.5 % rdg + 10 dgts). AC Voltage Resolution: 0.1 V in 400 V range. Peak Hold Measurement AC Current (40-450 Hz) Ranges: 400 A, 600 A. Peak Hold Measurement AC Current Accuracy: ± (2 % rdg + 10 dgts). AC Current Resolution: 0.1 A in 400 A range. Overload Protection Voltage: 1000 V DC / 750 V AC. Overload Protection Current: 800 Amps. Display: 3-3/4 digit, LCD, max reading of 3999.
|