AMPROBE ACD-41PQ CALIBRATION and AMPROBE ACD-41PQ REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE ACD-41PQ Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE ACD-41PQ   Description / Specification:   Spec Sheet 
AMPROBE ACD-41PQ 1000 Amp Power Quality Clamp Meter with THD Measurement

The Amprobe ACD-41PQ Power Quality Clamp Meter with THD Measurement provides a simple and effective way to verify if the electrical system is affected by harmonics (Total Harmonic Distortion to 51st harmonic). Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit. TRMS sensing. Specifications. AC Current: 40.0 / 400.0 / 1000 A. AC Current Basic Accuracy: +/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz. DC Voltage: 600.0V. DC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 LSD). AC Voltage: 600.0V. AC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz. Resistance: 999.9 ohm. Resistance Basic Accuracy: +/-(1.0% Rdg + 6 LSD). Frequency: 5.00 Hz to 500.0 Hz. Frequency Basic Accuracy: +/-(0.5% Rdg +4 LSD). THD-F: 0.0% to 99.9%. THD-F Basic Accuracy: 1.5% of Reading + 6d @ Fundamental Frequency. Active Power (W): 0 to 600.0 kW. Active Power (W) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics fundamental to 10th & PF > 0.7. Reactive Power (VAR): 0 to 600.0 kVAR. Reactive Power (VAR) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics fundamental to 10th & PF > 0.7. Apparent Power (VA): 0 to 600.0 kVA. Apparent Power (VA) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics fundamental to 10th. Power Factor: 0.10 to 0.99. Power Factor Basic Accuracy: +/- 3 LSD @ Harmonics Fund to 21th. Temperature: -58°F to 572° F (-50° C to 300° C). Temperature Basic Accuracy: +/-(2.0% Rdg + 6°F) +/-(2.0 % Rdg + 3°C).



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE ACD-41PQ. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your AMPROBE ACD-41PQ CALIBRATION and/or AMPROBE ACD-41PQ 1000 Amp Power Quality Clamp Meter with THD Measurement REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: