AMPROBE ACD-31P CALIBRATION and AMPROBE ACD-31P REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE ACD-31P Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE ACD-31P   Description / Specification:   Spec Sheet 
AMPROBE ACD-31P 1000 Amp Power Quality Clamp Meter with Temperature

The Amprobe ACD-31P 1000A Clamp-on Power Meter combines the standard features of professional clamp-on meters, with full Power analyzing capabilities. Measure: Active (W), Reactive (VAR) and Apparent (VA) Powers along with dual display Power Factor readout. Increase your ability to analyze the data with an optional PC interface kit. TRMS sensing. Specifications. AC Current: 40.0 / 400.0 / 1000 A. AC Current Basic Accuracy: +/-(0.5% Rdg + 5 d) @ 50 and 60Hz. AC Voltage: 600.0V. AC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 d) @ 50 / 60 Hz. DC Voltage: 600.0V. DC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 LSD). Resistance: 000.0 to 999.9 ohm. Resistance Basic Accuracy: +/-(1.0% Rdg + 6 d). Frequency: 5.00 Hz to 500.0 Hz. Frequency Basic Accuracy: +/-(0.5% Rdg +4 d). Temperature: -50°F to 572° F (-50° C to 300° C). Temperature Basic Accuracy: +/-(2.0% Rdg + 6°F)@ -4°F to 572°F, +/-(2.0 % Rdg + 3°C) @ -20°C to 300°C. Total Power Factor: 0.10 to 0.99. Total Power Factor Basic Accuracy: +/- 3 d @ Harmonics Fund to 21th. Power (VA): 0 to 600.0 kVA. Power (VA) Basic Accuracy: +/-(2.0% Rdg + 6 d) @ Harmonics fundamental to 10th. Power (kW and kVAR): 0 to 600.0 kW / kVAR. Power (kW and kVAR) Basic Accuracy: +/-(2.0% Rdg + 6 d) @ Harmonics fundamental to 10th & PF = 0.99 to 0.70. Audible Continuity Tester Threshold: between 10 ohms and 300 ohms.



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE ACD-31P. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your AMPROBE ACD-31P CALIBRATION and/or AMPROBE ACD-31P 1000 Amp Power Quality Clamp Meter with Temperature REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: