AMPROBE PM55A CALIBRATION and AMPROBE PM55A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE PM55A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   AMPROBE PM55A   Description / Specification:   Spec Sheet 
AMPROBE PM55A Pocket Multimeter with VolTect Non-Contact Voltage Detection

The Amprobe PM55A Pocket Multimeter with VolTect Non-Contact Voltage Detection is only 3/8” thick and less than 3 oz in weight with full functionality offering ac and dc voltage to 600 V, AC and DC current to 2000 µA, resistance to 6 Megohm, capacitance to 2000 µF, frequency to 30 kHz, diode test and continuity w/beeper. It also offers VolTect, a built-in, non-contact voltage detector for AC voltages. It automatically selects between AC voltage, DC voltage or resistance measurement based on the test point to which the leads are connected. Fully autoranging, this meter offers nine different measurement functions. Specifications. DC Voltage: 6.000 V ± (0.5 %+3 dgt), 60.00 V ± (1.0 %+5 dgt), 600 V (AutoTect Lo-Z) 2.0 %, 600 V (Hi-Z only) 1.5 % + 5 dgt. AC Voltage (50 Hz - 60 Hz): 6.000 V, 60.00 V, 600 V ± (1.5 %+5 dgt). Capacitance: 100.0 nF, 1000 nF, 10.0 µF, 100.0 µF, 2000 µF ± (3.5 %+6 dgt). Resistance: 600.0 ohm ± (2.0%+6 dgt), 6.000 Kohm ± (1.2%+6 dgt), 60.00 Kohm, 600.0 Kohm ± (1.0%+4 dgt), 6.000 Mohm ± (2.0%+4 dgt). Frequency: 10.00 Hz - 30.00 kHz ± (0.5 %+4 dgt) < 2 0 V Sine-rms, 10.00 Hz - 999.9 Hz ± (0.5 %+4 dgt) < 600 V Sine-rms. DC µA Current: 400.0 µA ± (1.5 %+3 dgt), 2000 µA ± (1.2 %+3 dgt). AC µA Current: 400.0 µA ± (2.0 %+3 dgt), 2000 µA ± (1.5 %+3 dgt). Diode Tester Test current: 0.48 mA. Display and update rate: 3-5/6 digits 6000 counts; Updates 5 per second nominal.



 

Standard Calibration $70.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE PM55A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your AMPROBE PM55A CALIBRATION and/or AMPROBE PM55A Pocket Multimeter with VolTect Non-Contact Voltage Detection REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: