Keysight (Agilent) U2723A REPAIR and Keysight (Agilent) U2723A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) U2723A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) U2723A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   Keysight (Agilent) U2723A   Description / Specification:   Spec Sheet 
Keysight (Agilent) U2723A 20V/120mA USB Modular Source Measure Unit

The Agilent U2723A USB Modular Source Measure Unit is an expanded version of the standard U2722A USB Modular Source Measure Unit. It includes embedded test scripts that will simplify automated testing with up to two test scripts per channel. The 3-channel 20V/120mA module can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity - allowing users to set up and configure their tests swiftly with its plug and play feature. Specifications. Number of outputs: 3. Voltage Output: –20 V to 20 V. Current Output: –120 mA to 120 mA. Voltage programming Ranges: ±2 V, ±20 V. Voltage programming Max Resolution: 0.1 mV. Current programming Ranges: ±1 µA, ±10 µA, ±100 µA, ±1 mA, ±10 mA, ±120 mA. Current programming Max Resolution: 100 pA. Voltage readback Ranges: ±2 V, ±20 V. Voltage readback Max Resolution: 0.1 mV. Current readback Ranges: ±1 µA, ±10 µA, ±100 µA, ±1 mA, ±10 mA, ±120 mA. Current readback Max Resolution: 100 pA. Remote sense operating range: Ensure that the maximum voltage between the OUTPUT+ and SENSE+, OUTPUT–, and SENSE– does not exceed 3 V. Temperature coefficient: Maximum change in output/readback per °C after a 30-minute warm-up is 0.15. Guard output resistance: 0.2 kohm. Noise 10 Hz to 20 MHz (peak-peak): 100 mV typical into a resistive load (floating mode). Output voltage overshoot, ±(% of output + offset): During turn-on or turn-off, the output plus overshoot < 0.1% + 10 mV. Programming language: SCPI (Standard Commands for Programmable Instruments). Maximum sense lead resistance: 1 M-ohm for rated accuracy.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) U2723A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) U2723A REPAIR and/or Keysight (Agilent) U2723A 20V/120mA USB Modular Source Measure Unit CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: