ANRITSU MS4645A CALIBRATION and ANRITSU MS4645A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MS4645A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU MS4645A   Description / Specification:   Spec Sheet 
ANRITSU MS4645A 50 GHz VectorStar Vector Network Analyzer

The Anritsu MS4645A 50 GHz VectorStar Vector Network Analyzer, 2-port, V(male) offers a new level of performance for device modeling engineers struggling to accurately and reliably characterize their devices, for R&D engineers pushing the last fraction of a dB out of their state-of-the-art designs, and for the manufacturing engineer trying to maximize throughput without sacrificing accuracy. Anritsu's MS4645A VNA offers the broadest coverage in a single instrument, 10 MHz to 50 GHz. The additional two decades at the low end are even more impressive than the guaranteed 50 GHz coverage on the high end, for better device modeling without having to switch to another RF VNA. The industry leading 100 dB dynamic range at 50 GHz. Specifications. Frequency Range: 10 MHz to 50.5 GHz. System Dynamic Range at Ports 1 or 2: 122 dB (0.01 to 2.5 GHz), 116 dB (2.5 to 5 GHz), 115 dB (5 to 20 GHz), 116 dB (20 to 38 GHz), 115 dB (38 to 50 GHz). Receiver Dynamic Range at Ports 1 or 2: 120 dB (0.01 to 50 GHz). Receiver Compression at Ports 1 or 2: 10 dBm (10 MHz to 50 GHz). Noise Floor: -110 dBm (0.01 to 50 GHz). Power Range: +12 to –25 dBm (0.01 to 2.5 GHz), +6 to –20 dBm (2.5 to 5 GHz), +6 to –25 dBm (20 to 38 GHz), +5 to –25 dBm (38 to 50 GHz). Output Default Power: -3 dBm. Power Accuracy: ± 1.5 dB (0.01 to 40 GHz), ± 3.0 dB (40 to 50 GHz). Power Linearity: ± 1.0 dB (0.01 to 50 GHz). Frequency Resolution: 1 Hz. Frequency Accuracy: ± 5 x 10^-7 Hz/Hz (at time of calibration). Typical 20 µs/point is achieved in true swept mode, with 25,000 points. 2-Port Measurements: S11, S21, S22, S12, and any user-defined combination of a1, a2, b1, b2, and 1. IF Bandwidth: 1, 3, 10, 30, 100, 300 Hz; 1, 3, 10, 30, 100, and 300 kHz; 1 MHz. GPIB Ports: GPIB Port (Talker/Listener), GPIB Port (Dedicated Controller). Options. 002 - Time Domain with advanced capabilities. 004 - Additional Solid State Drive (SSD), Serial-ATA. 007 - Receiver Offset with Multiple Source Control for frequency-translated measurements. 041 - Noise Figure (Option 51, 61 or 62 required). 051 - Direct Access Loops for total measurement flexibility. 061 - Active Measurement Suites with 2 attenuators. 062 - Active Measurement Suites with 4 attenuators. 070 - 70 kHz Low-end Frequency Extension. 080 - Modular Broadband connection capability. 081 - Modular Broadband connection capability. 082 - Milllimeter Wave Interface. 083 - Milllimeter Wave Interface.



 

Standard Calibration $985.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MS4645A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Spurious Signals
Spurious signals are undesired signals. They can be considered in two classes. They can be stationary; their frequency and amplitude do not change significantly, or non-stationary, where the frequency and/or amplitude change significantly over short time periods.


Please contact us for your ANRITSU MS4645A CALIBRATION and/or ANRITSU MS4645A 50 GHz VectorStar Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: