A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) N4420B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another S-Parameter Test Set?
Shop for Comparable Products on our
 used S-Parameter Test Set page

 
   Keysight (Agilent) N4420B   Description / Specification:   Spec Sheet 
Keysight (Agilent) N4420B 50 ohm 40 GHz S-Parameter Test Set

The Agilent N4421B S-parameter test set, combined with a 2-port PNA or PNA-L network analyzer and Option 550, offers a complete solution for 4-port measurements. Solid-state switches for fast and reliable measurement. Balanced measurement capability. Test set typical performance. Frequency range: 10 MHz to 40 GHz. Transition time: (10 to 90%) 14 ps. Impedance: 50 Ohms (nom). Maximum operating level: +20 dBm. Damage level: +30 dBm. Test port connectors: 2.4 mm (m). RF connectors: 2.4 mm (f). Dynamic range: Transmission measurements at 10 Hz IF bandwidth, with four-port error correction. Option 425: Front panel access to source output, receiver inputs and couplers for a custom test set. Adds source attenuators for wider source power output. Compatible network analyzers, N5230A. Option 550: Enables full, 4-port error correction and differential measurements on a 2-port network analyzer. External test set required. Compatible network analyzers, E8362/3/4B, E8361A, N5230A. Option 014: Provides front panel access to source output, receiver inputs and couplers to configure a custom test set. Compatible network analyzers, E8362/3/4B, E8361A, N5250A.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) N4420B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.


Please contact us for your Keysight (Agilent) N4420B CALIBRATION and/or Keysight (Agilent) N4420B 50 ohm 40 GHz S-Parameter Test Set REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: