BK PRECISION 5492B CALIBRATION and BK PRECISION 5492B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 5492B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   BK PRECISION 5492B   Description / Specification:   Spec Sheet 
BK PRECISION 5492B True RMS Bench Multimeter

The B&K Precision 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service repair, and manufacturing. It has built-in math functions and USB connectivity; Rel, Max/Min, dBm, dB, %, and Hold functions provide educators with a convenient tool to teach basic math concepts. Additionally, the 5492B offers powerful features such as advanced triggering, buffer storage operation, and a GPIB interface option. The 5492B measures volts and amps with great accuracy and stability, with basic VDC accuracy of 0.01%. The meter is also capable of measuring frequency, period, resistance, continuity, and performing diode tests. Readings can be taken at a maximum rate of 57 readings/sec and stored to an internal 512-byte buffer for post acquisition statistical analysis. Specifications. DC Voltage Ranges: 120.000 mV, 1.20000 V, 12.0000 V, 120.000 V, 1000.00 V. AC Voltage (True RMS, AC coupled) Ranges: 120.000 mV, 1.20000 V, 12.0000 V, 120.000 V, 750.00 V. DC Current Ranges: 12.0000 mA, 120.000 mA, 1.20000 A, 12.0000 A. AC Current (True RMS, AC Coupled) Ranges: 12.0000 mA, 1.20000 A, 12.0000 A. Resistance (2-Wire and 4-Wire) Ranges: 120.000 ohm, 1.20000 k-ohm, 12.0000 k-ohm, 120.000 k-ohm, 1.20000 M-ohm, 12.0000 M-ohm, 120.000 M-ohm. Continuity Range: 1 k-ohm. Diode Range: 3.0000 V (1 mA), 10.0000 V (100 µA), 10.0000 V (10 µA). Frequency (100 mV to 750 V) Ranges: 5 ~ 10 Hz, 10 ~ 100 Hz, 100 ~ 100 kHz, 100 k ~ 1 MHz. Period (100 mV to 750 V) Ranges: 1 ~ 10 µs, 10 µs ~ 10 ms, 10 ms ~ 100 ms, 100 ms ~ 200 ms. Math Functions: Rel, Max/Min/Average/StdDev (for stored readings), dB, dBm, Limit Test, % and mX+b. Interfaces: RS232, USB (virtual COM) GPIB (model 5492BGPIB only).



 

Standard Calibration $140.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 5492B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your BK PRECISION 5492B CALIBRATION and/or BK PRECISION 5492B True RMS Bench Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: