JDSU OLT-55 2286/01 CALIBRATION and JDSU OLT-55 2286/01 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the JDSU OLT-55 2286/01 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Lightwave Measurement System?
Shop for Comparable Products on our
 used Lightwave Measurement System page or new Lightwave Measurement System page

 
   JDSU OLT-55 2286/01 (2286-01)   Description / Specification:    
JDSU OLT-55 2286/01 1310/1550 nm SMART Optical Loss Test Set

The JDSU OLT-55 2286/01 SMART Optical Loss Test Set is a universal instrument combining a light source and a power meter in a single unit for singlemode fibers from lab through to installation, maintenance and troubleshooting. Independent quick referencing for all built-in wavelengths while the instrument is in measurement mode by connecting the source and power meter via a patch fiber cable. Built-in auto-zeroing for very low power levels or high loss measurements. Specifications. Loss Test Mode Nominal wavelengths: 1310/1550 nm. Spectral width (RMS): 5 nm. Fiber type: 9/125 µm. Signal stability Short term: ± 0.02 dB, within 15 min. Dynamic range: 60 dB. Resolution: 0.01 dB. Linearity: ± 0.06 dB ± 0.04 nW. Power Meter Mode Adjustable wavelength range: 780 to 1650 nm in 1 nm increments. Photo Diode: Germanium (GE). Display range: - 70 to +20 dBm. Resolution: 0.01 dB. Source Mode Nominal wavelengths: 1310/1550 nm. Spectral width (RMS): 5 nm. Fiber type: 9/125 µm. Output power range: -7 dBm to 0 dBm, separately adjustable. Resolution of power setting: 0.01 dB. Signal stability Short term: ± 0.02 dB, within 15 min. Output power accuracy at Nominal wavelengths: ± 0.3 dB. Options include Visual Fault Locator, Host USB data storage.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the JDSU OLT-55 2286/01. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Flatness
Variation of insertion loss on the passband of an optical device.

Polarization Dependent Loss (PDL)
Polarization Dependent Loss is the difference between the maximum and minimum values of loss due to the variation of the polarization states of light propagating through a device. PDL is expressed in decibels. Calculated by; PDL = 10 log10 (Ep/Es), where EP and ES are the measured diffraction efficiencies for P- and S-plane polarized incident light, respectively.

Return Loss (RL)
Return Loss (RL) is the ratio of the incident power to the reflected power expressed in dB. RL = 10log (Pin/Pback)

Wavelength Resolution
Wavelength Resolution is the smallest possible displayed wavelength increment/decrement.


Please contact us for your JDSU OLT-55 2286/01 CALIBRATION and/or JDSU OLT-55 2286/01 1310/1550 nm SMART Optical Loss Test Set REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: