JDSU OLT-55 2286/01 CALIBRATION and JDSU OLT-55 2286/01 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the JDSU OLT-55 2286/01 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Lightwave Measurement System?
Shop for Comparable Products on our
 used Lightwave Measurement System page or new Lightwave Measurement System page

 
   JDSU OLT-55 2286/01 (2286-01)   Description / Specification:    
JDSU OLT-55 2286/01 1310/1550 nm SMART Optical Loss Test Set

The JDSU OLT-55 2286/01 SMART Optical Loss Test Set is a universal instrument combining a light source and a power meter in a single unit for singlemode fibers from lab through to installation, maintenance and troubleshooting. Independent quick referencing for all built-in wavelengths while the instrument is in measurement mode by connecting the source and power meter via a patch fiber cable. Built-in auto-zeroing for very low power levels or high loss measurements. Specifications. Loss Test Mode Nominal wavelengths: 1310/1550 nm. Spectral width (RMS): 5 nm. Fiber type: 9/125 µm. Signal stability Short term: ± 0.02 dB, within 15 min. Dynamic range: 60 dB. Resolution: 0.01 dB. Linearity: ± 0.06 dB ± 0.04 nW. Power Meter Mode Adjustable wavelength range: 780 to 1650 nm in 1 nm increments. Photo Diode: Germanium (GE). Display range: - 70 to +20 dBm. Resolution: 0.01 dB. Source Mode Nominal wavelengths: 1310/1550 nm. Spectral width (RMS): 5 nm. Fiber type: 9/125 µm. Output power range: -7 dBm to 0 dBm, separately adjustable. Resolution of power setting: 0.01 dB. Signal stability Short term: ± 0.02 dB, within 15 min. Output power accuracy at Nominal wavelengths: ± 0.3 dB. Options include Visual Fault Locator, Host USB data storage.



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the JDSU OLT-55 2286/01. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your JDSU OLT-55 2286/01 CALIBRATION and/or JDSU OLT-55 2286/01 1310/1550 nm SMART Optical Loss Test Set REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: