A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 33521A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   Keysight (Agilent) 33521A   Description / Specification:    
Keysight (Agilent) 33521A 30 MHz, 1 Ch Function / Arbitrary Waveform Generator

The Agilent 33521A is a 30 MHz synthesized waveform generator with built-in arbitrary waveform and pulse capabilities. It’s a combination of bench-top and system generator. With 16 standard waveforms, built-in 16-bit 250 MSa/s arbitrary waveform capability and precise pulse waveform capabilities with adjustable edge time makes this waveform generator a versatile solution for your testing requirements.
Specifications.

Maximum frequency: 30 MHz.
Number of channels: one.
Standard Waveforms: Sine, Square, Ramp, Pulse, Triangle, Gaussian Noise, PRBS (Pseudorandom Binary Sequence), DC.
Built-in Arbitrary: Cardiac, Exponential Fall, Exponential Rise, Gaussian Pulse, Haversine, Lorentz, Negative Ramp, Sinc.
User-defined Arbitrary: Up to 1 MSa (16 MSa with Option 002) with multi segment sequencing.
Operating Modes : Continuous, Modulate, Frequency Sweep, Burst, Output Gate.
Modulation Types: AM, FM, PM, FSK, BPSK, PWM, Sum (carrier + modulation).
Voltage Level (nom): 3 Vpp into open circuit, 1.5 Vpp into 50 Ω.
Output Impedance (nom): 50 Ω.

Waveform Characteristics.
Sine.
Frequency Range: 1 μHz to 30 MHz, 1 μHz resolution.
Square and Pulse.
Frequency Range: 1 μHz to 30 MHz, 1 μHz resolution.
Rise and Fall Times (nom);
  Square: 8.4 ns, fixed.
  Pulse: 8.4 ns to 1 μs, independently variable, 100 ps or 3-digit resolution.
Ramp and Triangle.
Frequency Range: 1 μHz to 200 kHz, 1 μHz resolution.
Ramp Symmetry: 0.0% to 100.0%, 0.1% resolution (0% is negative ramp, 100% is positive ramp, 50% is triangle).
Gaussian Noise.
Bandwidth (typ): 1 mHz to 30 MHz, variable.
Crest Factor (nom): 4.6.
Repetition period: > 50 years.
Pseudorandom Binary Sequence.
Bit Rate: 1 mbps to 50 Mbps, 1 mbps resolution.
Sequence Length: 2^m-1, m=7, 9, 11, 15, 20, 23.

Options.
002 Increases Arbitrary Waveform memory from 1 MSa/channel to 16 MSa/channel.
010 High-stability frequency reference.
400 GPIB interface.



 

Standard Calibration $375.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 33521A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) 33521A CALIBRATION and/or Keysight (Agilent) 33521A 30 MHz, 1 Ch Function / Arbitrary Waveform Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: