FLUKE DSP-4100 CALIBRATION and FLUKE DSP-4100 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE DSP-4100 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE DSP-4100 (DSP4100)   Description / Specification:    
FLUKE DSP-4100 LAN CableAnalyzer

The Fluke DSP-4100 LAN CableAnalyzer is a hand-held instruments used to certify, test, and troubleshoot coaxial and twisted pair cable in local area network (LAN) installations. The test tool combines test pulses with digital signal processing to provide fast, accurate results and advanced testing capabilities up to 350 MHz. It certifies LAN basic link and channel configurations to IEEE, ANSI, TIA, and ISO/IEC standards. The DSP-4100 stores at least 250 grapical test reports on a removeable memory card. It produces plots of NEXT, ELFEXT, PSNEXT, PSELFEXT, attenuation, ACR, PSACR, and RL. Shows NEXT, ELFEXT, PSNEXT, PSELFEXT, attenuation, ACR, and PSACR results up to 350 MHz. Gives remote results for NEXT, PSNEXT, ACR, and RL. Specifications. Range Twisted Pair Cable: 0 ft to 328 ft, 328 ft to 2500 ft. Resolution Twisted Pair Cable: 1 ft or 0.1 m. Accuracy Twisted Pair Cable: ± (1 ft (0.3 m) + 2 % of reading) (0 ft to 328 ft), ± (1 ft (0.3 m) + 4 % of reading) (328 ft to 2500 ft). Range Coaxial Cable: 0 ft to 328 ft, 328 ft to 4000 ft. Resolution Coaxial Cable: 1 ft or 0.1 m. Accuracy Coaxial Cable: ± (1 ft (0.3 m) + 2 % of reading) (0 ft to 328 ft), ± (1 ft (0.3 m) + 4 % of reading) (328 ft to 4000 ft). Display: Graphic bit-mapped LCD with backlight and adjustable contrast.



 

Standard Calibration $550.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE DSP-4100. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your FLUKE DSP-4100 CALIBRATION and/or FLUKE DSP-4100 LAN CableAnalyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: