YOKOGAWA WT1803 CALIBRATION and YOKOGAWA WT1803 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA WT1803 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   YOKOGAWA WT1803   Description / Specification:    
YOKOGAWA WT1803 Three Input Element High Performance Power Analyzer

The Yokogawa WT1803 Three Input Element High Performance Power Analyzer has innovative functions that help improve measurement efficiency; Motor, Inverter, Lighting, EV/HEV, Battery, Power Supply, Aircraft, New Energy, Power Conditioner. Direct input of measurement signals makes it possible to measure very small current that can hardly be measured with a current sensor. The WT1803 provides a direct input voltage range from 1.5 V to 1000 V (12 ranges) and a direct input current range from 10 mA to 5 A (9 ranges) or from 1 A to 50 A (6 ranges). The frequency lower limit has been reduced to 0.1 Hz from the previous 0.5 Hz (5-fold lower than the previous model) to meet the requirement for power measurements at a low speed. Furthermore, high-speed data collection at a data update rate of up to 50 ms has been inherited. In addition to normal measurement data, up to the 500th order harmonic data can be measured and saved simultaneously. The data update rate can be selected from nine options from 50 ms to 20 s. Specifications. Basic power accuracy (50/60Hz): 0.1% of reading + 0.05% of range. Power frequency range: DC, 0.1 Hz ~ 1 MHz. Input elements: 3. Voltage range: 1.5/ 3/ 6/ 10/ 15/ 30/ 60/ 100/ 150/ 300/ 600/ 1000 [V]. Current range (direct input): 10m/ 20m/ 50m/ 100m/ 200m/ 500m/ 1/ 2/ 5 [A] or 1/ 2/ 5/ 10/ 20/ 50 [A]. Current range (external sensor input): 50m/ 100m/ 250m/ 500/ 1/ 2.5/ 5/ 10 [V]. Guaranteed accuracy range for voltage and current: 1% to 110%. Basic voltage/current accuracy: +/-0.1%. Basic power accuracy: +/-0.05%. Frequency range: DC, 0.1Hz to 1 MHz. Voltage/Current frequency range (-3 dB, typical): 5 MHz. Sampling speed: approximately 2 MS/s. Data update rate: 50 m, 100 m, 200 m, 500 m, 1, 2, 5, 10, 20 [sec]. Line filter: OFF, digital filter 100 Hz to 100 kHz (100 Hz step) analog filter 300 kHz, 1 MHz. Frequency filter: OFF, 100 Hz or 1 kHz. Fundamental frequency of the PLL source: 0.5 Hz to 2600 Hz (internal sampling clock), without external sampling clock function. Display: 8.4-inch color TFT LCD display, Total number of pixels* 1024 (horizontal) × 768 (vertical) dots. Options. /EX3, External current sensor input. /B5, Built-in printer. /G5, Harmonic Measurement. /G6, Simltaneous Dual Harmonic Measurement. /DT, Delta Computation. /FQ, Add-on Frequency Measurement. /V1, RGB output. /DA, 20-channel DA Outputs. /MTR, Motor Evaluation Function. /AUX, Auxiliary Sensor Inputs. /HS, High speed data capturing.



 

Standard Calibration $540.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA WT1803. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your YOKOGAWA WT1803 CALIBRATION and/or YOKOGAWA WT1803 Three Input Element High Performance Power Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: